COOL − Using the Cool Mode

COOL − Using the Cool Mode

Enabling and Disabling Cool Mode

Use the COOL button to enable or disable cool mode as desired. If the thermostat is in HEAT or OFF mode, cool mode is enabled when the COOL button is pressed. This is indicated by COOL in the SYSTEM box (see figure 9).

 

 

Turn Cool ON/OFF

 

 

Heat

Cool

MO

 

 

 

AM I0:30

FAN

Day/Time

 

HOLD

Prog

 

AUTO

 

ROOM

 

SYSTEM

 

SETPOINT COOL

 

75° 70°

Fan

Hold

 

 

Settings Enter

Figure 9

If the thermostat is in cool mode, pressing the Cool button disables COOL mode (indicated by OFF in the SYSTEM box − see figure 10).

Cool Mode Disabled

ROOM

SYSTEM

°SETPOINT

75 75° OFF

Figure 10

Cooling Demand

Set the thermostat to cool mode to control the cooling equipment. Then, if the room temperature is higher than the temperature setpoint, as shown in figure 11, the ther- mostat detects a cooling demand and will activate the cool- ing equipment to satisfy the demand.

 

Cooling Demand

 

MO TU WE TH FR SA SU

 

AM

 

 

 

FAN

PM i0:00

ON

 

 

HOLD

 

AUTO

 

 

 

 

ROOM

 

 

 

SYSTEM

75

°

SETPOINT

 

COOL

70

°

OFF

 

Hi

 

 

 

 

HEAT

 

 

 

 

Figure 11

Cooling operation is indicated by flashing nowflake" icons in the SYSTEM box. When the actual temperature drops below the temperature setpoint, the snowflake icons will disappear. This indicates that the cooling demand has been satisfied and that the cooling equipment has been turned off.

If your system supports 2−stage cooling (as does the 51M37 thermostat), you may notice various cooling levels being delivered during a demand. Also, if a small cooling demand is present, "Lo" will be displayed in the SYSTEM box. However, if a large cooling demand is present, "Hi" will be displayed in the SYSTEM box (shown in figure 11).

NOTE − If no buttons are pressed during a demand for cooling, the equipment must operate for at least 4 minutes. After a demand has been satisfied, cooling equipment op- eration is locked out for 5 minutes. If another cooling de- mand occurs during this 5−minute interval,

snowflakes will flash; however, the cooling equipment will not operate until the 5−minute delay has elapsed.