NOTE − This thermostat will NOT automatically switch from heating to cooling, or vice versa; operator involve- ment is required. At the change of seasons, or to accomo- date abnormal seasonal temperature swings, you must manually select to the opposite conditioning (Heat or Cool) program.

FAN − Controlling the Fan Operation

Use the FAN button to select either continuous fan mode or auto fan mode.

To change from continuous to auto fan mode (or vice ver- sa), press the FAN button. Note whether a fan icon in the FAN box is present (indicating that the fan is running) or not (fan not running).

If continuous fan mode is enabled (ON displayed in FAN box − see figure 13), the fan will run continuously regard- less of whether the heating or cooling equipment is run- ning.

Using Fan ON

Heat Cool

MO

PM I0:I0

ON

 

AM

FAN

 

PROG B

Prog

Day/Time

 

 

 

SYSTEM

 

ROOM

 

 

67°

Fan

Hold

 

HEAT

 

 

Settings

Enter

Figure 13

If auto fan mode is selected (AUTO displayed in FAN box − see figure 14), the fan will only run when the heating or cooling equipment is running.

 

Using Fan Auto

 

 

 

Heat

Cool

MO

 

Prog

Day/Time

PM I0:36 FAN

AM

 

 

 

PROG B

AUTO

 

 

ROOM

SYSTEM

 

 

COOL

 

 

72°

 

Fan

Hold

 

 

 

 

Settings Enter

Figure 14

SETTINGS − Filter/Maintenance Reminders

The 51M34 thermostat is designed to remind you when the filter needs changing or when routine maintenance is re- quired, as (and if) defined, by you. These optional remind- ers are not enabled until you activate them. To do so, press the Settings button (shown below the Fan button in figure

14)once or twice for the desired reminder as shown in fig- ure 15 and as described in table 1.

Reminder Settings Display

 

 

 

 

For MAINT,

 

 

MAINT

 

OFF

 

 

press Settings

 

 

 

 

FILTER

 

button 2 times

 

 

 

For FILTER,

 

 

 

 

 

 

 

 

 

 

press Settings

 

 

 

 

button 1 time

 

 

 

 

 

Figure 15

The default setting for the reminders is OFF (disabled). Press Up/Down arrow buttons to select the desired re- minder intervals.

Table 1

Filter and Maintenance Reminders

Buttons to

 

Available Settings and

Use

Reminder

How to Use

 

 

 

Settings

FILTER

Total fan run time expressed in

(1st press)

 

months (Off, 1, 3, 6, 12); for

 

then Arrows

 

example, if fan runs 12 hours a

to scroll

 

day, 1 month reminder displays

selections

 

in 2 calendar months.

 

 

 

Settings

MAINT

Elapsed chronological time in

(2nd press)

 

months (Off, 6, 12). Use this,

 

then Arrows

 

for example, to remind yourself

to scroll

 

when to perform routine checks

selections

 

or when to call a technician for

 

 

perodic preventive

 

 

maintenance.

 

 

 

Enter

 

Stores settings.

 

 

 

NOTE − The HOME screen will reappear about 15 seconds after the final arrow button press. OR, press ENTER at any time to store any changes and exit to the HOME screen.

After either programmed interval has elapsed, the remind- er will be displayed as shown in figure 16.

Reminders

 

 

 

MAINT

 

 

MO TU WE TH FR SA SU

 

FILTER

 

 

 

PM I0:i2

 

FAN

 

 

 

 

 

 

SERVICE

 

AM

 

 

 

 

 

 

 

AUTO

 

PROG

 

 

 

 

 

 

 

 

 

 

ROOM

SYSTEM

78°

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 16

 

 

 

After the filter has been changed, reset the filter reminder by pressing the SETTINGS button for 4 seconds. The screen will blink for a few moments to indicate that the tim- er has been reset.

Page 5

51M34 SERIES 5/2

Page 23
Image 23
Lennox International Inc 51M37 operation manual Pm, PM I0 36 FAN, FAN − Controlling the Fan Operation, Reminders