Delta Electronics VFD-L Series ΚΤϔϟϭ ϡϼΘγϻ ϝϭϷ Ϟμϔϟ, 002 0.2 KW 004 0.4 KW 007 0.75 KW 015 1.5 KW

Page 3

κΤϔϟ΍ϭ ϡϼΘγϻ΍ – ϝϭϷ΍ Ϟμϔϟ΍

˯Ύϴѧη΃ ϙΎѧϨϫ . ΓήΧΎѧΒϟ΍ ϲѧϓ ϊϠδѧϟ΍ ϦΤѧη ϞѧΒϗ ϊϨμѧϤϟ΍ ϲѧϓ ΔΒόѧλϭ ΔϴѧγΎϗ ϢѧϜΤΗ Ε΍έΎΒΘΧϻ ΔόοΎΧ VFD – L ήΗήϔϧϻ΍ ΔϠδϠγ

:ήΗήϔϧϻ΍ ϡϼΘγ΍ ΪόΑ ΔϴϟΎΘϟ΍ ΕΎλϮΤϔϟ΍ ˯΍ήΟ· ˯ΎΟήϟ΍ ˬ ΓήΧΎΒϟ΍ ϲϓ ϭ΃ Γή΋Ύτϟ΍ ϲϓ ϦΤθϟ΍ ˯ΎϨΛ΃ ΙΪΤΗ ΎϤΑέ ΓΪϳΪϋ

. ϦΤθϟ΍ ˯ΎϨΛ΃ ϩέήπΗ ϡΪόϟ ήΗήϔϧϼϟ Ϧϴϣ΄Θϟ΍ Ϛλ ϭ΃ ΔϟΎϔϜϟ΍ Ϧϣ Ϊϛ΄Η -1

.ϚϳΪϟ ΔΑϮϠτϤϟ΍ ˯΍ΰΟϷ΍ ΩΪϋ ϊϣ ΎϬϘΑΎσϭ ΔϴϤγϻ΍ ΔΣϮϠϟ΍ ϰϠϋ Δϟ΍Ϊϟ΍ ˯΍ΰΟϷ΍ ΩΪϋ Ϧϣ Ϊϛ΄Η -2 ΖϟϮϓ 230 ϭ ϥΎμΣ 1 ήΗήϔϧϻ ϝΎΜϣ : ΔϴϤγϻ΍ ΔΣϮϠϟ΍ ΕΎϣϮϠόϣ

:ΝΫϮϤϨϟ΍ ΢ϴοϮΗ

ήϴϐΘϤϟ΍ ΩΩήΘϟ΍ ΓΩΎϴϗ : VFD ΐγΎϨϤϟ΍ ϙήΤϤϟ΍ ΔϋΎτΘγ΍ : 07

002:0.2 KW

004 : 0.4 KW

007 : 0.75 KW

015 : 1.5 KW

VFD – L ΔϠδϠγ : L ϞΧΪϟ΍ ΪϬΟ : 21

έϮτϟ΍ ϱΩΎΣ΃ - ΖϟϮϓ 115 : 11

έϮτϟ΍ ϱΩΎΣ΃ – ΖϟϮϓ 230 : 21

έϮτϟ΍ ϲΛϼΛ – ΖϟϮϓ 230 : 23

ΔΨδϨϟ΍ : A

(ΪΣϮϣ) ϲγΎϴϗ : A

(ϲδϴσΎϨϐϣϭήϬϜϟ΍ ζϳϮθΘϟ΍ ΓήΘϠϓ ) ΓήΘϠϓ ϦϤπΘϣ : B

: ϲϠδϠδΘϟ΍ Ϣϗήϟ΍ ΢ϴοϮΗ

ΞΘϨϤϟ΍ ϊϨμϤϟ΍ : T 2003 ΝΎΘϧϹ΍ ΔϨγ : 3 ΝΎΘϧϹ΍ ωϮΒγ΃ : 10 ΝΎΘϧϹ΍ Ϣϗέ :001

.ϞϴϛϮϟΎΑ ϝΎμΗϻ΍ ˯ΎΟήϟ΍ ˬ ΔϠϜθϣ ϱ΃ ϭ΃ ϚϳΪϟ ˯΍ήθϟ΍ ΕΎΒϠσ ϊϣ ΔϘΑΎτΘϣ ήϴϏ ΔϴϤγϻ΍ ΔΣϮϠϟ΍ ϰϠϋ ΕΎϣϮϠόϣ Δϳ΃ ΕΪΟϭ ΍Ϋ·

2

Image 3
Contents Page Ύϭθϓ ήΗήϔϧϻ ΐϴϛήΗ ΔϣΪϘϣΚΤϔϟϭ ϡϼΘγϻ ϝϭϷ Ϟμϔϟ 002 0.2 KW 004 0.4 KW 007 0.75 KW 015 1.5 KWϦΤθϟ ˯ΎϨΛ ϩέήπΗ ϡΪόϟ ήΗήϔϧϼϟ Ϧϴϣ΄Θϟ Ϛλ ϭ ΔϟΎϔϜϟ Ϧϣ Ϊϛ΄Η ΩΎόΑϷ ϹγΎγϷ ϞϴλϮΘϟ ςτΨϣ ϞϴλϮΘϟ ϲϧΎΜϟ ϞμϔϟϢϜΤΘϟ ΓέΩ ϞϴλϮΗ ΐϴϛήΘϟ ϞΒϗ ϲϠϳ Ύϣ Γ˯ήϗ ˯ΎΟήϟ ϞϴλϮΘϟ ΕΎψΣϼϣ ΐγΎϨϣϭ ϲϓΎϛ ϡΰόΑ ΓΩϭΪθϣ ϲϏήΒϟ ϊϴϤΟ ϥ Ϧϣ Ϊϛ΄Η ϪθβϩηϞϣΎΤϟ ΩΩήΘϟ ξϴϔΨΘΑ Ύπϳ˱ ϲδϴσΎϨϐϣϭήϬϜϟ ζϳϮθΘϟ κϘϨϳ ϥ ϦϜϤϳ ΕήΘϣέΎΒϟ κΨϠϣ ΚϟΎΜϟ Ϟμϔϟ ΈΎϬχϹ ΔηΎη Ϧϣ ϑΎϘϳϹ 10.0 ~ 600 secΔϴϤϗήϟ έΎϬχϹ ΔηΎη ϹϬΑΎθΘϟ ϞΧΪϟ ΪϬΟ Ϧϣ 0 ~ 10 V RS 485 ϝΎμΗϻ άϔϨϣ ΔϴϤϗήϟ έΎϬχϹ ΔηΎη ϡΪΨΘγΎΑ~ 350 Hz ϠΪΨΘδϣ ήϴϏ ΉΗήϔϧϻ ϞϤϋ ˯ΎϨΛ ϞϤόΗΘΪϬϟ ΩΩήΘϠϟ ϝϮλϮϟ PLC ΞϣΎϧήΑ ϞϴϐθΗ PLC ΞϣΎϧήΑ ϝΎϤΘϛ65500 Sec ΔϨϜϤϣ ήϴϏ PLC ˰ϟ ΔϴϠϤϋϹδϜϋ SecΪΰϟ ϡΰόϟ ΔψΣϼϣ ΪόΑ 390 ϜΎόϓ ήϴϏ350 ~ 410 170 ϜΎόϓ ήϴϏ 20 ~ 200 % ϜΎόϓ ήϴϏ~ 5.0 Sec ~ 30 %~ 60.0 Sec ~ 400.0 Sec~ 20 Sec 1~20 Modbus ˰ϟ 4800 ϝΎγέϹ Δϋήγ 9600 ϝΎγέϹ Δϋήγ19200 ϝΎγέϹ Δϋήγ ϦϜϤϣ ήϴϏϜΎτϋϷ ΕΎϣϮϠόϣϭ ϝΎτϋϷ ήμΣ ϊΑήϟ Ϟμϔϟ ϘήΤϤϟ ϲϓ ϞϤΘΤϣ Ϟτϋ ΩϮΟϭ Ϧϣ ϖϘΤΗ ΪΟ˱ ϝΎϋ ϡΰόϟ ϊϓέ ΩέΎδΘϟ Ϧϣί ΓΩΎϳΰΑ ϢϗΉΒϛ ΝήΧ ΔϋΎτΘγΎΑ ήΗήϔϧϻ ϝΪΒΘγ ΪΟ˱50/60 Hz ± 5 % 230 115 015 007 004 002ϹΛϼΛ 180 -264 V 50/60Hz

VFD-L Series specifications

Delta Electronics has established itself as a leader in variable frequency drive (VFD) technology, with the introduction of the VFD-L Series serving as a testament to their commitment to innovation and performance. These drives are designed specifically for various applications in industries such as HVAC, pumps, fans, and conveyors, offering users enhanced control and energy efficiency.

One of the main features of the VFD-L Series is its compact design, which allows for easy installation even in space-constrained environments. The drives are built with a rugged casing that provides excellent protection in harsh operating conditions, making them ideal for industrial settings. With power ratings spanning from 0.4 kW to 37 kW, the VFD-L Series caters to a wide range of applications, ensuring that users can find the right solution to meet their needs.

Incorporating advanced control algorithms, the VFD-L Series enhances motor performance while maintaining energy efficiency. The drives utilize Vector Control technology, which provides precise speed and torque control for AC induction and permanent magnet motors. This capability allows for smooth acceleration and deceleration, minimizing mechanical stress on equipment and prolonging lifespan.

The VFD-L Series is equipped with a built-in programmable logic controller (PLC) functionality, enabling users to customize control sequences without the need for additional external devices. This feature simplifies system design and enhances operational flexibility. Additionally, the user-friendly interface allows for easy programming and monitoring, making it accessible for both novice and experienced users.

Another noteworthy characteristic is the incorporation of energy-saving features. The VFD-L Series includes sleep mode and automatic energy optimization functions that proactively adjust the motor’s power consumption based on the actual load requirements. This not only reduces operational costs but also contributes to environmental sustainability by lowering carbon emissions.

Furthermore, Delta Electronics has ensured that the VFD-L Series is compliant with international standards, providing users with confidence in their reliability and safety. With built-in protection features like overvoltage, undervoltage, overload, and short-circuit protection, these drives provide a secure operating environment for sensitive equipment.

In conclusion, Delta Electronics’ VFD-L Series combines advanced technology, robust features, and a compact design to deliver exceptional performance across various industrial applications. With a focus on energy efficiency and user-friendly accessibility, the VFD-L Series is a powerful solution for modern manufacturing and automation needs. Whether for HVAC systems or material handling, this series stands out as an innovative choice for businesses looking to enhance their operational efficiency.