THERMAL CURVES
|
| H48SR1R880(Standard) Output Current vs. Ambient Temperature and Air Velocity |
|
| |||||||
Output Current(A) |
| @ Output Voltage 0.8V (Either Orientation) |
|
|
|
| |||||
88 |
|
|
|
|
|
|
|
|
|
|
|
80 |
|
|
|
|
|
|
|
| 600LFM |
| |
|
|
|
|
|
|
|
|
|
|
| |
72 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 500LFM |
|
64 |
|
|
|
|
|
|
|
|
|
|
|
56 |
| Natural |
|
|
|
|
|
|
| 400LFM |
|
| Convection |
|
|
|
|
|
|
|
| ||
48 |
|
|
|
|
|
|
|
|
|
|
|
40 |
|
| 100LFM |
|
|
|
|
|
|
|
|
32 |
|
|
|
|
|
|
|
|
|
|
|
24 |
|
|
| 200LFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
16 |
|
|
|
|
| 300LFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
8 |
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 |
|
|
|
|
|
|
|
|
| Ambient Temperature (℃) |
Figure 18: Hot spot location (unit in mm) | Figure 19: Output current vs. ambient temperature and air |
| velocity (Vin=48V / 75V, Vout=0.8V ) |
| H48SR1R880(Standard) Output Current vs. Ambient Temperature and Air Velocity |
| ||||||||
Output Current(A) |
| @ Output Voltage 1.8V (Either Orientation) |
|
|
|
| ||||
88 |
|
|
|
|
|
|
|
|
|
|
80 |
|
|
|
|
|
|
|
| 600LFM |
|
|
|
|
|
|
|
|
|
|
| |
72 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 500LFM |
|
64 |
|
|
|
|
|
|
|
|
|
|
56 | Natural |
|
|
|
|
|
|
| 400LFM |
|
| Convection |
|
|
|
|
|
|
|
| |
48 |
|
|
|
|
|
|
|
|
|
|
40 |
|
| 100LFM |
|
|
|
|
|
|
|
32 |
|
|
|
|
|
|
|
|
|
|
24 |
|
|
| 200LFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
16 |
|
|
|
| 300LFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
8 |
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
|
|
|
|
|
|
|
|
| Ambient Temperature (℃) |
|
| H48SR1R880(Standard) Power Dissipation vs. Ambient Temperature and Air Velocity |
| ||||||||
Power Dissipation (Watts) |
|
| (Either Orientation) |
|
|
|
|
| |||
24 |
|
|
|
|
|
|
|
|
|
|
|
21 |
|
|
|
|
|
|
|
| 600LFM |
| |
|
|
|
|
|
|
|
|
|
|
| |
18 |
|
|
|
|
|
|
|
|
| 500LFM |
|
15 |
|
|
|
|
|
|
|
|
|
|
|
|
| Natural |
|
|
|
|
|
|
| 400LFM |
|
| Convection |
|
|
|
|
|
|
|
|
| |
12 |
|
|
|
|
|
|
|
|
|
|
|
9 |
|
| 100LFM |
|
|
|
|
|
|
|
|
6 |
|
|
|
| 200LFM |
|
|
|
|
|
|
3 |
|
|
|
|
| 300LFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
0 |
|
|
|
|
|
|
|
|
|
|
|
0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 |
|
|
|
|
|
|
|
|
| Ambient Temperature (℃) |
Figure 20: Output current vs. ambient temperature and air velocity (Vin=48V / 75V, Vout=1.8V )
Figure 21: Power dissipation vs. ambient temperature and air velocity (Vin=48V / 75V, Vout=0.8V~1.8V )
7