Image 116
Foreign Configuration Not Found in <Ctrl><R> Error Message

Foreign Configuration Not Found in <Ctrl><R> Error Message

Error Message: The foreign configuration message is present during POST but no foreign configurations are present in the foreign view page in CTRL+R. All virtual disks are in an optimal state.

Corrective Action: Ensure all your PDs are present and all VDs are in optimal state. Clear the foreign configuration using <Ctrl><R> or Dell OpenManage Server Administrator Storage Management.

CAUTION: The physical disk goes to Ready state when you clear the foreign configuration.

If you insert a physical disk that was previously a member of a virtual disk in the system, and that disk’s previous location has been taken by a replacement disk through a rebuild, you must manually remove the foreign configuration flag of the newly inserted disk.

Previous Configuration Cleared or Missing Error Message

Error Message: Previous configuration(s) cleared or missing. Importing configuration created on XX/XX XX.XX. Press any key to continue, or ’C’ to load the configuration utility.

Probable Cause: The message indicates that the controller and physical disks have different configurations.

Corrective Action: You can use the BIOS Configuration Utility (<Ctrl><R>) to clear the foreign configuration.

Invalid SAS Topology Detected Error Message

Error Message: Invalid SAS topology detected. Please check your cable configurations, repair the problem, and restart your system.

Probable Cause: The SAS cables for your system are improperly connected.

Corrective Action: Check the cable connections and fix problems if any. Restart the system.