Dell H310, H710P manual Redundant Path Support For PERC H810 Only

Models: H310 H710 H710P H810

1 136
Download 136 pages 19.9 Kb
Page 29
Image 29
Redundant Path Support (For PERC H810 Only)

Patrol Read does not run on any disks involved in any of the following operations:

Rebuild

Replace Member

Full or Background Initialization

CC

RLM or OCE

NOTE: By default, Patrol Read automatically runs every seven days on configured SAS and SATA hard drives. Patrol Read is not necessary on SSD and is disabled by default.

For more information on Patrol Read, see the Dell OpenManage documentation at support.dell.com/manuals.

Redundant Path Support (For PERC H810 Only)

The PERC H810 adapter can detect and use redundant paths to disks contained in enclosures. This provides the ability to connect two SAS cables between a controller and an enclosure for path redundancy. The controller is able to tolerate the failure of a cable or Enclosure Management

Module (EMM) by utilizing the remaining path.

When redundant paths exist, the controller automatically balances I/O load through both paths to each disk. Load balancing increases throughput to virtual disks in storage enclosures and is automatically turned on when redundant paths are detected. The ability to load balance I/O can be disabled using the Dell OpenManage storage management application.

To set up your hardware to support redundant paths, see "Setting up Redundant Path Support on the PERC H810 Adapter" on page 40.

NOTE: This support for redundant paths refers to path-redundancy only and not to controller-redundancy.

Features

29

Page 29
Image 29
Dell H310, H710P manual Redundant Path Support For PERC H810 Only