Dell H310, H710P, H810 manual Multibit ECC Errors Detected Error Messages

Models: H310 H710 H710P H810

1 136
Download 136 pages 19.9 Kb
Page 117
Image 117
Multibit ECC Errors Detected Error Messages

Multibit ECC Errors Detected Error Messages

NOTE: The following error is specific to the PERC H710 controller only.

Error Message: Multibit ECC errors were detected on the RAID controller. If you continue, data corruption can occur. Contact technical support to resolve this issue. Press 'X' to continue or else power off the system, replace the controller and reboot.

Or

Error Message: Multibit ECC errors were detected on the RAID controller.The DIMM on the controller needs replacement. If you continue, data corruption can occur. Press 'X' to continue or else power off the system, replace the DIMM module, and reboot. If you have replaced the DIMM please press 'X' to continue.

CAUTION: Multi-bit ECC errors cause data corruption and data loss. In case of MBE errors, contact Dell Technical Support.

Probable Cause: Multi-bit ECC errors occur in the memory and can corrupt cached data and discard it.

Corrective Action: Contact Dell Technical Support.

Configured Disks Removed or Not Accessible Error Message

Error Message: Some configured disks have been removed from your system or are no longer accessible. Check your cables and ensure all disks are present. Press any key or ’C’ to continue.

Probable Cause: The message indicates that some configured disks were removed. If the disks were not removed, they are no longer accessible. The SAS cables for your system might be improperly connected.

Corrective Action: Check the cable connections and fix any problems. Restart the system. If there are no cable problems, press any key or <C> to continue.

Troubleshooting

117

Page 117
Image 117
Dell H310, H710P Multibit ECC Errors Detected Error Messages, Configured Disks Removed or Not Accessible Error Message