Dell H710P SMART Errors, Smart Error Detected on a Physical Disk in a Redundant Virtual Disk

Models: H310 H710 H710P H810

1 136
Download 136 pages 19.9 Kb
Page 124
Image 124
SMART Errors

SMART Errors

SMART monitors the internal performance of all motors, heads, and physical disk electronics and detects predictable physical disk failures.

NOTE: For information about where to find reports of SMART errors that could indicate hardware failure, see the Dell OpenManage storage management documentation at support.dell.com/manuals.

Smart Error Detected on a Physical Disk in a Redundant Virtual Disk

Issue: A SMART error is detected on a physical disk in a redundant virtual disk.

Corrective Action:

Perform the following steps:

1Back up your data.

2Force the physical disk offline.

NOTE: If a hot spare is present, the rebuild starts with the hot spare after the disk is forced offline.

3Replace the disk with a new physical disk of equal or higher capacity.

4Perform the Replace Member operation.

The Replace Member operation allows you to copy data from a source physical disk of a virtual disk to a target physical disk that is not a part of the virtual disk. For more information about the Replace Member feature, see "Using Replace Member and Revertible Hot Spares" on page 31.

124

Troubleshooting

Page 124
Image 124
Dell H710P, H310, H810 SMART Errors, Smart Error Detected on a Physical Disk in a Redundant Virtual Disk, Corrective Action