Dell H310, H710P, H810 Replace Member Errors, Source Disk Fails During Replace Member Operation

Models: H310 H710 H710P H810

1 136
Download 136 pages 19.9 Kb
Page 125
Image 125
Smart Error Detected on a Physical Disk in a Non-Redundant Virtual

Smart Error Detected on a Physical Disk in a Non-Redundant Virtual

Issue: A SMART error is detected on a physical disk in a redundant virtual disk.

Corrective Action:

Perform the following steps:

1Back up your data.

2Use Replace Member or set up a global hot spare to replace the disk automatically.

For more information about the Replace Member feature, see "Using Replace Member and Revertible Hot Spares" on page 31.

3Replace the affected physical disk with a new physical disk of equal or higher capacity.

4Restore from the backup.

Replace Member Errors

NOTE: For more information about the Replace Member features, see "Using Replace Member and Revertible Hot Spares" on page 31.

Source Disk Fails During Replace Member Operation

Issue: The source disk fails during the Replace Member operation.

Corrective Action: If the source data is available from other disks in the virtual disk, the rebuild begins automatically on the target disk, using the data from the other disks.

Target Disk Fails

Issue: The target disk fails.

Corrective Action: If the target disk fails, the Replace Member operation aborts.

General Disk Fails

Issue: A general disk fails.

Troubleshooting

125

Page 125
Image 125
Dell H310 Replace Member Errors, Smart Error Detected on a Physical Disk in a Non-Redundant Virtual, Target Disk Fails