![Smart Error Detected on a Physical Disk in a Non-Redundant Virtual](/images/new-backgrounds/136505/136505249x1.webp)
Smart Error Detected on a Physical Disk in a Non-Redundant Virtual
Issue: A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective Action:
Perform the following steps:
1Back up your data.
2Use Replace Member or set up a global hot spare to replace the disk automatically.
For more information about the Replace Member feature, see "Using Replace Member and Revertible Hot Spares" on page 31.
3Replace the affected physical disk with a new physical disk of equal or higher capacity.
4Restore from the backup.
Replace Member Errors
NOTE: For more information about the Replace Member features, see "Using Replace Member and Revertible Hot Spares" on page 31.
Source Disk Fails During Replace Member Operation
Issue: The source disk fails during the Replace Member operation.
Corrective Action: If the source data is available from other disks in the virtual disk, the rebuild begins automatically on the target disk, using the data from the other disks.
Target Disk Fails
Issue: The target disk fails.
Corrective Action: If the target disk fails, the Replace Member operation aborts.
General Disk Fails
Issue: A general disk fails.
Troubleshooting
125