Jumpers and Connectors

This section provides specific information about the system jumpers. It also provides some basic information on jumpers and switches and describes the connectors on the various boards in the system.

System Board Jumpers

Figure 6-1 shows the location of the configuration jumpers on the system board. Table 6-1 lists the jumper settings.

Table 6-1. System Board Jumper Settings

Jumper

Setting

Description

PWRD_EN

(default) The password feature is enabled (pins 2-4)

The password feature is disabled,

and iDRAC6 local access is unlocked at the next AC power cycle (pins 4-6)

NVRAM_CLR

(default) The configuration settings are retained at system boot (pins 3-5)

The configuration settings are cleared at the next system boot (pins 1-3)

Jumpers and Connectors

193

Page 193
Image 193
Dell R510 System Board Jumpers, Default The password feature is enabled pins, 193, System Board Jumper Settings