![](/images/new-backgrounds/1110907/11090779x1.webp)
Code | Text | Causes | Corrective Actions |
|
|
|
|
E2113 | Mem mirror OFF | The system BIOS has | Remove AC power to the |
| on DIMM ## & | disabled memory | system for 10 seconds and |
| ##. Power | mirroring because it has | restart the system. |
| cycle AC | determined one half of the | If the problem persists, |
|
| mirror has had too many | see "Troubleshooting |
|
| errors. "## & ##" | |
|
| System Memory" on | |
|
| represents the | |
|
| page 177. | |
|
| ||
|
|
| |
|
| implicated by the BIOS. |
|
|
|
|
|
I1910 | Intrusion | System cover has been | Information only. |
| detected. | removed. |
|
| Check chassis |
|
|
| cover. |
|
|
I1912 System Event | The SEL is full of events |
Log full. | and is unable to log any |
Review & | more. |
clear log. |
|
Check the SEL for details on the events, then clear the SEL.
I1920 iDRAC6 Upgrade | Optional iDRAC6 has | Information only. |
Successful | been upgraded |
|
| successfully. |
|
W1228 RAID | Warns predictively that |
Controller | the RAID battery has |
battery | less than 24 hours of |
capacity < | charge left. |
24hr. |
|
Allow RAID battery to charge to greater than 24 hours of sustained charge.
If problem persists, replace RAID battery. See "Installing the RAID Battery" on page 147.
W1627 Power required The system configuration
>PSU wattage. requires more power
Check PSU and | than what the power |
config. | supply can provide. |
Turn off power to the system, reduce the hardware configuration or install
40