Message | Causes | Corrective Actions |
|
|
|
Alert! iDRAC6 not | The optional iDRAC6 is not | Wait for the system |
responding. | responding to BIOS | to reboot. |
Rebooting. | communication either |
|
| because it is not functioning |
|
| properly or has not |
|
| completed initialization. |
|
| The system reboots. |
|
Alert! iDRAC6 not responding. Power required may exceed PSU wattage.
Alert! Continuing system boot accepts the risk that system may power down without warning.
The optional iDRAC6 has hung.
The optional iDRAC6 was remotely reset while system was booting.
After AC recovery, the optional iDRAC6 takes longer than normal to boot.
Remove AC power to the system for 10 seconds and restart the system.
Alert! Node | The memory configuration | Ensure that the memory |
Interleaving | does not support node | modules are installed in a |
disabled! Memory | interleaving, or the | configuration that supports |
configuration | configuration has changed | node interleaving. |
does not support | (for example, a memory | Check other system |
Node | module has failed) so that | messages for additional |
Interleaving. | node interleaving cannot be | information for possible |
| supported. The system still | causes. For memory |
| runs, but without node | configuration information, |
| interleaving. | see "General Memory |
|
| Module |
|
| Installation Guidelines" on |
|
| page 115. If the problem |
|
| persists, |
|
| see "Troubleshooting System |
|
| Memory" on page 177. |
About Your System