Message

Causes

Corrective Actions

 

 

 

Alert! iDRAC6 not

The optional iDRAC6 is not

Wait for the system

responding.

responding to BIOS

to reboot.

Rebooting.

communication either

 

 

because it is not functioning

 

 

properly or has not

 

 

completed initialization.

 

 

The system reboots.

 

Alert! iDRAC6 not responding. Power required may exceed PSU wattage.

Alert! Continuing system boot accepts the risk that system may power down without warning.

The optional iDRAC6 has hung.

The optional iDRAC6 was remotely reset while system was booting.

After AC recovery, the optional iDRAC6 takes longer than normal to boot.

Remove AC power to the system for 10 seconds and restart the system.

Alert! Node

The memory configuration

Ensure that the memory

Interleaving

does not support node

modules are installed in a

disabled! Memory

interleaving, or the

configuration that supports

configuration

configuration has changed

node interleaving.

does not support

(for example, a memory

Check other system

Node

module has failed) so that

messages for additional

Interleaving.

node interleaving cannot be

information for possible

 

supported. The system still

causes. For memory

 

runs, but without node

configuration information,

 

interleaving.

see "General Memory

 

 

Module

 

 

Installation Guidelines" on

 

 

page 115. If the problem

 

 

persists,

 

 

see "Troubleshooting System

 

 

Memory" on page 177.

About Your System

43

Page 43
Image 43
Dell R510 owner manual Alert! iDRAC6 not, Responding, Rebooting, Alert! Node, Interleaving