Dell R510 Following DIMMs should, Thermal sensor, Not detected, Time-of-day, Clock stopped

Models: R510

1 216
Download 216 pages 48.79 Kb
Page 53
Image 53

Message

Causes

Corrective Actions

 

 

 

The following

Invalid memory

Ensure that the memory

DIMMs should

configuration. The specified

modules are installed in a

match in

memory modules do not

valid configuration.

geometry:

match in size, number of

See "General Memory

x,x,...

ranks, or number of

Module

The following

data lanes.

Installation Guidelines" on

 

page 115.

DIMMs should

 

 

 

match in rank

 

 

count: x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size:

 

 

x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size

 

 

and geometry:

 

 

x,x,...

 

 

The following

 

 

DIMMs should

 

 

match in size

 

 

and rank count:

 

 

x,x,...

 

 

 

 

 

Thermal sensor

A memory module without a

Replace the memory

not detected

thermal sensor is installed in

module. See "System

on x

the specified memory slot.

Memory" on page 114.

 

 

 

Time-of-day

Faulty battery or faulty chip.

See "Troubleshooting the

clock stopped

 

System Battery" on page 174.

 

 

 

Time-of-day not

Incorrect Time or Date

Check the Time and Date

set - please run

settings; faulty system

settings. See "Using the

SETUP program

battery.

System Setup Program and

 

 

UEFI Boot Manager" on

 

 

page 61. If the problem

 

 

persists, replace the system

 

 

battery. See "System Battery"

 

 

on page 143.