Message

Causes

Corrective Actions

 

 

 

Unused memory

The memory configuration is

Reconfigure the memory for

detected. DIMM’s

not optimal for Advanced

Advanced ECC Memory

installed in the

ECC Memory Mode.

Mode, or change the

following slot

Modules in the specified

memory mode to Optimized

are not available

slots are unused.

or Sparing in the BIOS setup

when in 128-bit

 

screen. See "System

advanced ECC

 

Memory" on page 114.

mode: x,x,x

 

 

 

 

 

Warning: A fatal

A fatal system error

Check the SEL for

error has caused

occurred and caused the

information that was logged

system reset!

system to reboot.

during the error. See the

Please check the

 

applicable troubleshooting

system event log!

 

section in "Troubleshooting

 

 

Your System" on page 169 for

 

 

any faulty components

 

 

specified in the SEL.

 

 

 

Warning: Control

The control panel is not

Install the control panel, or

Panel is not

installed or has a faulty cable

check the cable connections

installed.

connection.

between the display module,

 

 

the control panel board,

 

 

and the system board.

 

 

See "Integrated Storage

 

 

Controller Card" on

 

 

page 129.

 

 

 

Warning! No micro

Micro code update failed.

Update the BIOS firmware.

code update

 

See "Getting Help" on

loaded for

 

page 199.

processor n

 

 

56

About Your System

Page 56
Image 56
Dell R510 When in 128-bit, Error has caused, System reset, Please check, System event log, Panel is not, Code update