Code

Text

Causes

Corrective Actions

 

 

 

 

E122A

CPU # VTT

Specified processor

Reseat the processor(s).

 

Regulator

VTT voltage regulator

See "Troubleshooting

 

failure.

has failed.

Processors" on page 186.

 

Reseat CPU.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help" on

 

 

 

page 199.

E122C CPU Power

A power fault was

Fault. Power

detected when powering

cycle AC.

up the processor(s).

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 199.

E122D

Memory

One of the memory

Reseat the memory

 

Regulator #

regulators has failed.

modules. See

 

Failed.

 

"Troubleshooting System

 

Reseat DIMMs.

 

Memory" on page 177.

 

 

 

 

E122E

On-board

One of the on-board

Remove AC power to the

 

regulator

voltage regulators has

system for 10 seconds and

 

failed.

failed.

restart the system.

 

Call support.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help" on

 

 

 

page 199.

 

 

 

 

E1310

Fan ## RPM

RPM of specified fan is

See "Troubleshooting

 

exceeding

outside of the intended

System Cooling

 

range.

operating range.

Problems" on page 176.

 

Check fan.

 

 

 

 

 

 

E1313

Fan redundancy

The system is no longer

Check LCD for

 

lost.

fan redundant. Another

additional scrolling

 

Check fans.

fan failure would put the

messages. See

 

 

system at risk of

"Troubleshooting a Fan"

 

 

overheating.

on page 176.

About Your System

31

Page 31
Image 31