Dell R510 owner manual Troubleshooting a Hard Drive, 181

Models: R510

1 216
Download 216 pages 48.79 Kb
Page 181
Image 181

Troubleshooting a Hard Drive

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

CAUTION: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.

1Run the appropriate online diagnostics test. See "Using Online Diagnostics" on page 189.

Depending on the results of the diagnostics test, proceed as needed through the following steps.

2If installed, remove the front bezel. See "Removing the Front Bezel" on page 86.

3If your system has a RAID controller and your hard drives are configured in a RAID array, perform the following steps:

a Restart the system and enter the host adapter configuration utility program by pressing <Ctrl><R> for a PERC controller or <Ctrl><C> for a SAS controller.

See the documentation supplied with the host adapter for information about the configuration utility.

bEnsure that the hard drive(s) have been configured correctly for the RAID array.

cTake the hard drive offline and reseat the drive. See "Removing a Hot- Swap Hard Drive" on page 92

dExit the configuration utility and allow the system to boot to the operating system.

4Ensure that the required device drivers for your controller card are installed and are configured correctly. See the operating system documentation for more information.

Troubleshooting Your System