Dell H710P, H310, H810 manual RAID Terminology, Disk Striping

Models: H310 H710 H710P H810

1 136
Download 136 pages 19.9 Kb
Page 130
Image 130
RAID Terminology

RAID 10 is a combination of RAID 0 and RAID 1, uses disk striping across mirrored disks. It provides high data throughput and complete data redundancy. RAID 10 can support up to eight spans, and up to 32 physical disks per span.

RAID 50 is a combination of RAID 0 and RAID 5 where a RAID 0 array is striped across RAID 5 elements. RAID 50 requires at least six disks.

RAID 60 is a combination of RAID 0 and RAID 6 where a RAID 0 array is striped across RAID 6 elements. RAID 60 requires at least eight disks.

RAID Terminology

Disk Striping

Disk striping allows you to write data across multiple physical disks instead of just one physical disk. Disk striping involves partitioning each physical disk storage space in stripes of the following sizes: 64 KB, 128 KB, 256 KB, 512 KB, and 1024 KB. The stripes are interleaved in a repeated sequential manner. The part of the stripe on a single physical disk is called a stripe element.

For example, in a four-disk system using only disk striping (used in RAID 0), segment 1 is written to disk 1, segment 2 is written to disk 2, and so on. Disk striping enhances performance because multiple physical disks are accessed simultaneously, but disk striping does not provide data redundancy.

Figure A-1 shows an example of disk striping.

Figure A-1. Example of Disk Striping (RAID 0)

Stripe element 1

Stripe element 2

Stripe element 3

Stripe element 4

Stripe element 5

Stripe element 6

Stripe element 7

Stripe element 8

Stripe element 9

Stripe element 10

Stripe element 11

Stripe element 12

130

Appendix: RAID Description

Page 130
Image 130
Dell H710P, H310, H810 manual RAID Terminology, Disk Striping