Delta Electronics F48SA Design Considerations, Input Source Impedance, Safety Considerations

Page 8
DESIGN CONSIDERATIONS

DESIGN CONSIDERATIONS

Input Source Impedance

The impedance of the input source connecting to the DC/DC power modules will interact with the modules and affect the stability. A low ac-impedance input source is recommended. If the source inductance is more than a few μH, we advise adding a 220 to 470 μF electrolytic capacitor (ESR < 0.1 Ω at 100 kHz) mounted close to the input of the module to improve the stability.

Layout and EMC Considerations

Delta’s DC/DC power modules are designed to operate in a wide variety of systems and applications. For design assistance with EMC compliance and related PWB layout issues, please contact Delta’s technical support team. An external input filter module is available for easier EMC compliance design. Application notes to assist designers in addressing these issues are pending release.

Safety Considerations

The power module must be installed in compliance with the spacing and separation requirements of the end-user’s safety agency standard, i.e., UL60950, CAN/CSA-C22.2 No. 60950-00 and EN60950:2000 and IEC60950-1999, if the system in which the power module is to be used must meet safety agency requirements.

Basic insulation based on 75 Vdc input is provided between the input and output of the module for the purpose of applying insulation requirements when the input to this DC-to-DC converter is identified as TNV-2 or SELV. An additional evaluation is needed if the source is other than TNV-2 or SELV.

When the input source is SELV, the power module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc, for the module’s output to meet SELV requirements, all of the following must be met:

DS_F48SA28025_12072007

The input source must be insulated from the ac mains by reinforced or double insulation.

The input terminals of the module are not operator accessible.

If the metal baseplate is grounded, one Vi pin and one Vo pin shall also be grounded.

A SELV reliability test is conducted on the system where the module is used, in combination with the

module, to ensure that under a single fault, hazardous voltage does not appear at the module’s output.

When installed into a Class II equipment (without grounding), spacing consideration should be given to the end-use installation, as the spacing between the module and mounting surface have not been evaluated.

The power module has extra-low voltage (ELV) outputs when all inputs are ELV.

This power module is not internally fused. To achieve optimum safety and system protection, an input line fuse is highly recommended. The safety agencies require a normal-blow fuse with 20A maximum rating to be installed in the ungrounded lead. A lower rated fuse can be used based on the maximum inrush transient energy and maximum input current.

Soldering and Cleaning Considerations

Post solder cleaning is usually the final board assembly process before the board or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power module and severely affect the finished circuit board assembly test. Adequate cleaning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate soldering and cleaning procedures, please contact Delta’s technical support team.

8

Image 8
Contents FEATURES OPTIONSAPPLICATIONS DATASHEET DSF48SA2802512072007TECHNICAL SPECIFICATIONS INPUT CHARACTERISTICSOUTPUT CHARACTERISTICS DYNAMIC CHARACTERISTICSELECTRICAL CHARACTERISTICS CURVES 36Vin48Vin 75VinFor Negative Remote On/Off Logic For Positive Remote On/Off LogicFigure 7 Output voltage response to step-change in load Figure 12 Output voltage noise and ripple measurement test setup Figure 13 Output voltage ripple at nominal input voltage and rated load current 100 mV/div. Load capacitance470uF aluminum, 1µF ceramic capacitor and 10µFlow ESR capacitor. Bandwidth 20 MHz. Scope measurement should be made using a BNC cable length shorter than 20 inches. Position the load between 51 mm to 76 mm 2 inches to 3 inches from the module Safety Considerations Soldering and Cleaning ConsiderationsDESIGN CONSIDERATIONS Input Source ImpedanceFEATURES DESCRIPTIONS Over-Current ProtectionOver-Voltage Protection Over-Temperature ProtectionFEATURES DESCRIPTIONS CON Output Voltage Adjustment TRIMThermal Testing Setup THERMAL CONSIDERATIONSTHERMAL CURVES Thermal DeratingPin Specification MECHANICAL DRAWINGPin No NameWARRANTY PART NUMBERING SYSTEMMODEL LIST MODEL NAME