Delta Electronics Series V48SR manual Safety Considerations, Soldering and Cleaning Considerations

Page 7
Safety Considerations

DESIGN CONSIDERATIONS

Safety Considerations

The power module must be installed in compliance with the spacing and separation requirements of the end-user’s safety agency standard, i.e., UL60950, CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and IEC60950-1999, if the system in which the power module is to be used must meet safety agency requirements.

Basic insulation based on 75 Vdc input is provided between the input and output of the module for the purpose of applying insulation requirements when the input to this DC-to-DC converter is identified as TNV-2 or SELV. An additional evaluation is needed if the source is other than TNV-2 or SELV.

When the input source is SELV circuit, the power module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc, for the module’s output to meet SELV requirements, all of the following must be met:

The input source must be insulated from the ac mains by reinforced or double insulation.

The input terminals of the module are not operator accessible.

If the metal baseplate is grounded, one Vi pin and one Vo pin shall also be grounded.

A SELV reliability test is conducted on the system where the module is used, in combination with the

module, to ensure that under a single fault, hazardous voltage does not appear at the module’s output.

When installed into a Class II equipment (without grounding), spacing consideration should be given to the end-use installation, as the spacing between the module and mounting surface have not been evaluated.

The power module has extra-low voltage (ELV) outputs when all inputs are ELV.

This power module is not internally fused. To achieve optimum safety and system protection, an input line fuse is highly recommended. The safety agencies require a normal-blow fuse with 5A maximum rating to be installed in the ungrounded lead. A lower rated fuse can be used based on the maximum inrush transient energy and maximum input current.

Soldering and Cleaning Considerations

Post solder cleaning is usually the final board assembly process before the board or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power module and severely affect the finished circuit board assembly test. Adequate cleaning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate soldering and cleaning procedures, please contact Delta’s technical support team.

DS_V48SR15004_06122007

7

Image 7
Contents OPTIONS DC/DC Power Modules 48V in, 15V, 4.4A outDelphi Series V48SR, 1/16th Brick 66W FEATURESDYNAMIC CHARACTERISTICS TECHNICAL SPECIFICATIONSINPUT CHARACTERISTICS OUTPUT CHARACTERISTICSELECTRICAL CHARACTERISTICS CURVES For Positive Remote On/Off Logic For Negative Remote On/Off LogicFigure 12 Input reflected ripple current, is, through a 12µH Layout and EMC Considerations Schematic and ComponentsDESIGN CONSIDERATIONS Input Source ImpedanceSoldering and Cleaning Considerations Safety ConsiderationsOver-Temperature Protection FEATURES DESCRIPTIONSOver-Current Protection Over-Voltage ProtectionEx. When Trim-up +10% 15V×1.1=16.5V FEATURES DESCRIPTIONS CONOutput Voltage Adjustment TRIM Ex. When Trim-down -10% 15V×0.9=13.5VThermal Derating Thermal Testing SetupTHERMAL CONSIDERATIONS THERMAL CURVESSURFACE-MOUNT TAPE & REEL PICK AND PLACE LOCATIONRECOMMENDED PAD LAYOUT SMD Time LEADED Sn/Pb PROCESS RECOMMEND TEMP. PROFILELEAD FREE SAC PROCESS RECOMMEND TEMP. PROFILE TempName MECHANICAL DRAWINGSurface-mount module Through-hole moduleMODEL NAME PART NUMBERING SYSTEMMODEL LIST WARRANTY