Compaq S5 manual Introducing the 16-Bit UltraSCSI Hub Rack-Mountable, UltraSCSI Hub Features

Page 11

1

Introducing the 16-Bit UltraSCSI Hub (Rack-Mountable)

This chapter gives a brief physical description and describes the functions and functional specifications of the DWZZH-S5 and DWZZH-09 UltraSCSI Hubs.

The series of DWZZH Hubs are SCSI–2 and draft SCSI–3 (ANSI X379.2/91– 10R3) compliant capable with data transfer rates of up to 40 Mbytes per second. The two versions of these Hubs are:

DWZZH-S5: A shelf-contained, rack-mountable, 5.25" SBB (large) Hub with four host ports and one storage port, all differential. See Figure 1–1.

DWZZH-09:A shelf-contained, rack-mountable Hub consisting of two 5.25" SBBs (large) with eight host ports and one storage port, all differential. See Figure 1–2.

1.1 UltraSCSI Hub Features

Most device SCSI buses are either 8-bit or 16-bit single-ended, physical buses. Some controllers and hosts use differential buses and others use a single-ended bus. Single-ended and differential physical buses are not compatible. The UltraSCSI protocol disables both buses when they are connected together. By using an UltraSCSI Hub you can accomplish the following:

Provide radial disconnect where remaining connections can continue to operate.

Provide fair SCSI arbitration for host nodes (DWZZH-05, -S5 and the -09 UltraSCSI Hubs only).

EK-SMDZS-UG. B01

1-1

Image 11 Contents
Dwzzh 16-Bit UltraSCSI Hub Rack-Mountable Second edition, November Japanese Vcci StatementContents Tables FiguresRevision Level Date Summary of Changes Revision RecordPage Related Documentation About This GuideAudience Introducing the 16-Bit UltraSCSI Hub Rack-Mountable Document StructureGetting Help Page Introducing the 16-Bit UltraSCSI Hub Rack-Mountable UltraSCSI Hub FeaturesDWZZH-S5 Product Descriptions DWZZH-S5DWZZH-09 DWZZH-09Lists the functional specifications for the Dwzzh Hub Product SpecificationsDwzzh HUB Functional Specifications Cont’d Page Install 0.5m Cable in DWZZH-09 Setting Up the DWZZH-09Set Up DWZZH-09 Install Tri-link and Cable in Storage Ports of SBBs A Sample Configuration Maximum Allowable Cable Distances Configuration NoteLarge Hub Fair Arbitration Using the 16-Bit UltraSCSI HubNarrow Addressing Setting Large Hub Addressing ConfigurationsDWZZH-S5 Scsi ID Assignments DWZZH-09 Scsi ID Assignments Front PanelDWZZH-S5 Front Panel Indicators Fair ARB DisableDWZZH-S5 Scsi Narrow ID Assignments Selecting the Scsi Cables Determining the ConfigurationDWZZH-09 Upgrade Kit Contents Installing the DWZZH-09 Upgrade KitInstall 0.5m Cable Install UpgradeInstall power cords in power supplies on unit Page Agents and Storage Swcc and UltraSCSI HubsRunning One Swcc Agent for a Particular Storage Subsystem Part Number Description Removable Parts of the DWZZH-S5 and DWZZH-09Figure A-1 Removable Parts of the DWZZH-S5 Controller GlossarySBB Scsi cable