Compaq S5 manual Configuration Note, Maximum Allowable Cable Distances

Page 20

DWZZH 16–Bit UltraSCSI Hub (Rack-Mountable)

2.2Configuration Note

According to the UltraSCSI Configuration Guidelines (included in your purchase), the maximum allowable cable distance for an UltraSCSI Domain is 74 meters. Each element, including the DWZZH-09 has an associated relative cable distance value associated. Cables count as their specified distance, (including the 0.5 meter jumper cable between the SBB Hubs); but each DWZZH SBB counts as an 18.5 meter cable equivalent. This means that communications from a server attached to the left-hand SBB to a server attached to the right-hand SBB, already has a 37.5 meter cable equivalent distance cost to propagate the signal through the DWZZH-09 Hub. Therefore, if the distance from server A to the Hub is X, and the distance from server B to the Hub is Y, then the sum cable distance of X and Y must be less than or equal to 36.5 meters (74 – 37.5). Please note that any SCSI transaction from a host to the storage subsystem only propagates through one of the SBBs. This means that you may still have a cable length of 25 meters between the storage subsystem and the DS-DWZZH-09. Refer to Figure 2–4.

Figure 2–4 Maximum Allowable Cable Distances

2–4

EK–SMDZS–UG. B01

Image 20 Contents
Dwzzh 16-Bit UltraSCSI Hub Rack-Mountable Japanese Vcci Statement Second edition, NovemberContents Figures TablesRevision Record Revision Level Date Summary of ChangesPage Related Documentation About This GuideAudience Document Structure Introducing the 16-Bit UltraSCSI Hub Rack-MountableGetting Help Page UltraSCSI Hub Features Introducing the 16-Bit UltraSCSI Hub Rack-MountableProduct Descriptions DWZZH-S5 DWZZH-S5DWZZH-09 DWZZH-09Product Specifications Lists the functional specifications for the Dwzzh HubDwzzh HUB Functional Specifications Cont’d Page Install 0.5m Cable in DWZZH-09 Setting Up the DWZZH-09Set Up DWZZH-09 Install Tri-link and Cable in Storage Ports of SBBs A Sample Configuration Configuration Note Maximum Allowable Cable DistancesUsing the 16-Bit UltraSCSI Hub Large Hub Fair ArbitrationLarge Hub Addressing Configurations Narrow Addressing SettingDWZZH-S5 Scsi ID Assignments Front Panel DWZZH-09 Scsi ID AssignmentsDWZZH-S5 Front Panel Fair ARB Disable IndicatorsDWZZH-S5 Scsi Narrow ID Assignments Determining the Configuration Selecting the Scsi CablesInstalling the DWZZH-09 Upgrade Kit DWZZH-09 Upgrade Kit ContentsInstall Upgrade Install 0.5m CableInstall power cords in power supplies on unit Page Swcc and UltraSCSI Hubs Agents and StorageRunning One Swcc Agent for a Particular Storage Subsystem Removable Parts of the DWZZH-S5 and DWZZH-09 Part Number DescriptionFigure A-1 Removable Parts of the DWZZH-S5 Glossary ControllerSBB Scsi cable