2-2 Planning Repeater Installation
CAUTION: The power outlet must be a
NOTE: If the supplied power cord is lost or damaged, replace it with a power cord of the same type and current rating (10 A). The replacement cord should also meet required regulatory approvals to ensure emissions compliance.
Spatial Requirements
The repeater's dimensions are 3 x 16.95 x 14 inches, 7.62 x 43.05 x 35.56 cm (HxWxD).
You can interconnect two repeaters. If there is not enough space to mount the repeaters in a single rack or stack them on a single shelf, or if you want to place the repeaters in different locations, you can place them on separate shelves or in separate racks. See
Be sure to allow at least 2 inches (5.1 centimeters) on each side of the repeater for proper air circulation and cable connections.
Twisted-Pair (UTP) Wire Requirements
The
■The wiring must be unshielded
■Two pairs of the
■Depending on building codes, different insulation materials may be required.
■The wire gauge should be between 18 and 26 AWG. (Most telephone installations use