Compaq DS-DWZZH-05 manual Callout Number Description, BN21K or BN21L HD68 cable b

Page 18

Table 2–2: Hardware Components Used in the Configuration Shown in Figure 2–3

Callout Number

Description

1

BN38C HD68 to VHDCI cablea b

2

H885-AA HD68 trilink connector

 

 

3

H879-AA HD68 terminator

 

 

4

BN21K or BN21L HD68 cableb

aThe maximum length of the SCSI bus segment, including BN38C cable and internal device length, must not exceed 25 meters.

bThe maximum length of the SCSI bus segment, including the combined length of the BN38C and BN21K (or BN21L) cables, must not exceed 25 meters.

2.7.3.2 Cabling an HSZ70 to a DS-DWZZH-05 UltraSCSI Hub

To prepare the storage portion of a cluster using HSZ70 RAID array controllers, follow these steps while referring to Figure 2–4 and Table 2–3:

1.Install an H8861-AA trilink connector on each HSZ70 controller port on the SCSI bus segment.

2.Attach an H8863-AA terminator to the H8861-AA connector on the HSZ70 controller that will be on the end of the SCSI bus segment.

3.If there are two HSZ70 controllers, connect the two H8861-AA trilink connectors on the controllers with a BN37A cable.

4.Connect the DS-DWZZH-05 to the HSZ70 H8861-AA trilink with a BN37A cable.

_____________________ Note _____________________

The maximum length of a SCSI bus segment, including cable and internal device SCSI bus length must not exceed 25 meters.

Figure 2–4 shows a sample configuration that uses a KZPBA-CB SCSI adapter, a DS-DWZZH-05 UltraSCSI hub, and an HSZ70 RAID array controller.

2–10Using the DS-DWZZH-05 UltraSCSI Hub in a Cluster Configuration

Image 18
Contents December Operating System and Version Compaqs Digital Unix VersionCompaq Computer Corporation Houston, Texas Page Contents Tables Audience OrganizationPage DS-DWZZH-05 UltraSCSI Hub General OverviewDS-DWZZH Overview DS-DWZZH-05 UltraSCSI Hub Description DS-DWZZH-05 Configuration GuidelinesDS-DWZZH UltraSCSI Hub Maximum Configurations Disk Drivesa Personality Moduleb cDS-DWZZH-05 Fair Arbitration Disk Drives a Personality Module b cDS-DWZZH-05 Address Configurations DS-DWZZH-05 Front View Scsi Bus Termination Power DS-DWZZH-05 IndicatorsConfiguring a Cluster with a DS-DWZZH-05 Installing the DS-DWZZH-05 UltraSCSI Hub Cabling an HSZ50 to a DS-DWZZH-05 UltraSCSI Hub DS-DWZZH-05 Callout Number Description BN21K or BN21L HD68 cable bKZPBA-CB BN38C HD68 to Vhdci cablea