Compaq manual DS-DWZZH-05 Fair Arbitration, Disk Drives a Personality Module b c

Page 11

Table 2–1: DS-DWZZH UltraSCSI Hub Maximum Configurations (cont.)

DS-DWZZH-03

DW-DWZZH-05

Disk Drivesa

Personality

 

 

 

Moduleb c

1

1

2

Installed

 

 

 

 

0

1

3

Installed

aDS-DWZZH UltraSCSI hubs and disk drives may coexist in a storage shelf. Installed disk drives are not associated with the DS-DWZZH UltraSCSI hub SCSI bus segments; they are on the SCSI bus connected to the personality module.

bIf the personality module is installed, you can install a maximum of four DS-DWZZH-03 UltraSCSI hubs. cThe personality module must be installed to provide a path to any disks installed in the BA356 or DS-BA356 shelf.

2.3 DS-DWZZH-05 Fair Arbitration

Although each cluster member system and storage controller connected to an UltraSCSI hub are on separate SCSI bus segments, they all share a common SCSI bus and its bandwidth. As the number of systems accessing the storage controllers increases, it is likely that the adapter with the highest priority SCSI ID will obtain a higher proportion of the UltraSCSI bandwidth.

The DS-DWZZH-05 UltraSCSI hub provides a fair arbitration feature that overrides the traditional SCSI bus priority. Fair arbitration applies only to the member systems, not to the storage controllers (which are assigned higher priority than the member system host adapters).

You enable fair arbitration by placing the switch on the front of the DS-DWZZH-05 UltraSCSI hub to the Fair position (see Figure 2–1).

Fair arbitration works as follows. The DS-DWZZH-05 UltraSCSI hub is assigned the highest SCSI ID, which is 7. During the SCSI arbitration phase, the hub, because it has the highest priority, captures the SCSI ID of all host adapters arbitrating for the bus. The hub compares the SCSI IDs of the host adapters requesting use of the SCSI bus, and then allows the device with the highest priority SCSI ID to take control of the SCSI bus. That SCSI ID is removed from the group of captured SCSI IDs prior to the next comparison.

After the host adapter has been serviced, if there are still SCSI IDs retained from the previous arbitration cycle, the next highest SCSI ID is serviced.

When all devices in the group have been serviced, the DS-DWZZH-05 repeats the sequence at the next arbitration cycle.

Fair arbitration is disabled by placing the switch on the front of the DS-DWZZH-05 UltraSCSI hub in the Disable position (see Figure 2–1). With fair arbitration disabled, the SCSI requests are serviced in the

Using the DS-DWZZH-05 UltraSCSI Hub in a Cluster Configuration 2–3

Image 11
Contents Compaq Computer Corporation Houston, Texas DecemberOperating System and Version Compaqs Digital Unix Version Page Contents Tables Organization AudiencePage General Overview DS-DWZZH-05 UltraSCSI HubDS-DWZZH Overview DS-DWZZH-05 Configuration Guidelines DS-DWZZH-05 UltraSCSI Hub DescriptionDisk Drivesa Personality Moduleb c DS-DWZZH UltraSCSI Hub Maximum ConfigurationsDisk Drives a Personality Module b c DS-DWZZH-05 Fair ArbitrationDS-DWZZH-05 Address Configurations DS-DWZZH-05 Front View Configuring a Cluster with a DS-DWZZH-05 Scsi Bus Termination PowerDS-DWZZH-05 Indicators Installing the DS-DWZZH-05 UltraSCSI Hub Cabling an HSZ50 to a DS-DWZZH-05 UltraSCSI Hub DS-DWZZH-05 BN21K or BN21L HD68 cable b Callout Number DescriptionKZPBA-CB BN38C HD68 to Vhdci cablea