| P35i Fireplace Insert | |
|
|
|
|
9 |
| With proper installation, operation, and maintenance, your appliance will provide years of | |
| |||
Troubleshooting | qualified service person in proper diagnosis and repair. This guide is intended for qualified | ||
service technician use only. |
| ||
|
|
|
Error Message | Possible Cause | Corrective Action |
| |
Broken probe, wire or connection. | Check connection / Replace Probe | |||
|
|
|
| |
| Exhaust temperature has gone out of range | Clean exhaust- possible soot or creosote | ||
| multiple times. |
| accumulation near probe. | |
|
|
|
| |
Broken sensor, wire or connection. | Check connection / Replace sensor | |||
signal. |
|
|
|
|
| No fuel in hopper |
| Load fuel | |
| Door, hopper lid, or ash pan open | Close all doors and check seals | ||
Poor draft / weak combustion blower | Perform draft test, clean exhaust, replace blower if | |||
|
|
| necessary. | |
| Fuel feed restriction |
| Check operation in "Test" mode. Clear obstruction | |
| Blocked airflow / Igniter failure | Open burn pot cleanout to access igniter- clean. | ||
|
|
| Check igniter, replace if necessary | |
| No fuel in hopper |
| Load fuel | |
| Door, hopper lid, or ash pan open | Close all doors and check seals | ||
Poor draft / weak combustion blower | Perform draft test, clean exhaust, replace blower if | |||
| ||||
|
|
| necessary. | |
| Fuel feed restriction |
| Check operation in "Test" mode. Clear obstruction | |
|
|
|
|
|
Symptom | Possible Cause | Corrective Action |
| |
| No fuel in hopper |
| Load fuel | |
| Door, hopper lid, or ash pan open | Close all doors and check seals | ||
Low volume or no fuel feed | Poor draft / weak combustion blower | Perform draft test, clean exhaust, replace blower if | ||
| ||||
|
|
| necessary. | |
| Fuel feed restriction |
| Check operation in "Test" mode. Clear obstruction | |
| Failed feed motor |
| Replace motor if necessary | |
|
|
|
| |
| Fire isn't hot enough for blower operation | Increase temperature setting | ||
| MANUAL / STOVE TEMP | When operating in manual ignite / stove temp mode, | ||
No Distribution Blower |
|
| the blower will not run below a #3 setting on the | |
|
|
| temperature dial. Increase temperature setting. | |
| Failed motor or connections- "Test" mode | Check connections / Replace blower | ||
|
|
|
|
|
| Feed rate too low |
| Set feed adjuster at #4 or higher | |
| Room sensor location different than ther- | Room sensor reports the room air temperature to | ||
Low heat output, or room tem- | mometer location |
| the circuit board. Move sensor location or adjust set | |
perature doesn't match ther- |
|
| point accordingly | |
mometer or other readings | Excessive ash buildup on heat exchanger | Clean exhaust, firebox, and heat exchanger thor- | ||
| ||||
| or in the exhaust |
| oughly. | |
|
|
|
|
|
|
|
|
|
|
28 Pellets or Corn/Pellet Mixture Only | Save These Instructions |