Harman Stove Company P35I owner manual 1Listing and Code Approvals, A. Appliance Certification

Models: P35I

1 48
Download 48 pages 52.68 Kb
Page 4
Image 4
1Listing and Code Approvals

P35i Fireplace Insert

1Listing and Code Approvals

A. Appliance Certification

Model:

P35i Insert

Laboratory:

OMNI-Test Laboratories, Inc.

Report No.

135-S-25-6.2

Type:

Solid Fuel Room Heater / Fireplace

 

Insert.

Standard(s):

ASTM E1509-04, ULC S628-93 and

 

ULC/ORD C1482-M1990

This appliance is also approved for installation in a shop.

B. Mobile Home Approved

This appliance is approved for Installation in mobile/ manufactured homes. The structural integrity of the mobile home floor, ceiling and walls must be main- tained. The appliance must be properly grounded to the frame of the mobile home, and must never be installed in a room designated for sleeping. The unit must have provisions for an outside air source when installed in a mobile home.

E. BTU & Efficiency Specifications

Particulate Emissions

Exempt from EPA per

Rating:

40 CFR, Method 28A

*BTU Input:

0 or 6,000 - 35,000 / hr

 

 

Heating Capacity:

1,500 sq. ft.

Hopper Capacity-

41 lbs.

#1-70-774195 (19½ ")

 

Hopper Capacity-

62 lbs.

#1-70-774235 (23½ ")

 

 

 

Fuel:

Wood pellets / Corn†

Shipping Weight:

289 lbs.

*BTU input will vary, depending on the type of fuel you use in your stove. Moisture and ash content can affect performance.

† Corn is approved for burning only when mixed with wood pellets.

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass if needed.

D. Electrical Rating

115 VAC, 60 Hz,

3.6 Amps (Start-up); avg. 1.5 Amps (Normal Run)

4 Pellets or Corn/Pellet Mixture Only

3-90-775