D. Existing Fireplace Installation:

P35i Fireplace Insert

D. Existing Fireplace Installation:

If using a short run of venting, whether flex or rigid, through the damper and into the chimney flue; The Damper must be removed or locked in the open posi- tion and sealed with a plate constructed of steel or other non-combustible material.

Kaowool, mineral wool or other non-combustible insu- lation is recommended above the plate to reduce the possibility of condensation. You will also need to wrap the venting section between the insert frame and the damper sealing plate. This is to prevent overheating of the fireplace cavity, which may cause damage to the insert's motors and other electrical components. The connector pipe should extend through the sealing plate and smoke chamber and into, or beyond the first flue tile.

Be sure to design the venting so that it can be easily cleaned.

Check with your local authority having jurisdiction to determine if this venting method is acceptable. Some Provincial, State, or Local codes may require a full liner run to the top of the chimney. Be sure and check your local regulations before planning the installation. In this method, the proper flashing and rain cap are also required.

Non-combustible WARNING

Fire Risk.

Inspect Chimney

Masonry chimney must be in good condition

Meets minimum of NFPA 211 standard

Factory-built chimney must meet requirements of UL103 HT

IN CANADA: This fireplace insert

When venting in this configuration, a rain cap and

must be installed with a continuous

proper flashing must be installed on the top of the

chimney liner of a minimum 3"

chimney to prevent flooding and damage.

diameter extending from the insert to

the top of the chimney. The chimney

 

 

 

Liner

 

liner must conform to the Class 3

 

 

 

 

 

 

 

 

 

requirements of CAN/ULC-S635,

 

 

 

 

 

Standard for Lining Systems for

 

 

 

Flue

 

Existing Masonry or Factory Built

 

 

 

 

 

 

 

 

 

Chimneys and Vents, or CAN/ULC-

 

 

 

Tile

 

S640, Standard for Lining Systems

 

 

 

 

 

 

 

 

 

for New Masonry Chimneys.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-combustible

Insulation

Sealing PlateSealing PlateManual background

When using single wall flex, this section of venting must be wrapped with non-combustible insulation to prevent excessive heat build-up in the cavity.

Save These Instructions

3-90-775

Pellets or Corn/Pellet Mixture Only

15

Page 15
Image 15
Harman Stove Company P35I owner manual D. Existing Fireplace Installation, Non-combustible Insulation, Sealing Plate