F.Installing the Body into the Mounting Frame

P35i Fireplace Insert

F.Installing the Body into the Mounting Frame

The rollers on the sides of the insert body will ride on the rails of the mounting frame. Once the body is all the way in, hook and close the top spring latches on each side to secure.

Room sensor placed here gives an accurate measure of return air. Push the pre-cut hole inward, and feed the sensor from the back side. Allow the bulb of the sensor to extend approximately 1½ inches into the room. Use a wire tie on the push-in tab to secure the sensor wire.

G. Control Board Installation

The control board is packaged in a static resistant bag. Use care when handling, hold the circuit board only by the edges. In a large fireplace opening, you may have plenty of space for the circuit board to re- main attached. For a smaller fireplace opening, you'll likely need to remove the wiring from the circuit board to route it through the side of the mounting frame and out through the control opening. Follow these steps;

Disconnect the 11 pin harness plug.

Disconnect the red twisted ESP wire.

Feed the harness wires and the ESP wire through the opening in the mounting frame and out through the control opening in the surround panel.

Holding the control board outside the opening in the surround panel, re-attach the harness plug and the ESP wire.

After determining the location of the Room Sen- sor (See next Section), Attach it to the two male

spade terminals near the top of the circuit board. NOTE: These connections are not polarity specific.

From the power cord, attach the green ground wire to the grounding post located on the feeder air intake snout.

The black wire from the power cord gets attached to the short brown wire from the control harness

The white wire from the power cord will attach to the short white wire on the control harness.

Install the control panel into the surround; Right side first, then tilt in the left side.

Secure using the four black machine screws in- cluded with the surround.

H. Room Sensor Installation

Although not required, it is recommended that the room sensor be connected in every installation. Using a minimum size 18 gauge wire, you may splice in an additional length, to extend the room sensor. The fol- lowing are typical locations for the room sensor;

On an interior wall next to or in place of a typical wall thermostat.

On the leg of a coffee table or end table in your favorite sitting location.

Sticking out through the punched hole at the lower right corner of the control panel.

Note: When installing the room sensor externally, limit the distance from the stove to 25 feet or less.

Once the location has been decided, run the wiring to the control panel. You'll need to remove the two ter- minals from the end of the sensor cable and replace them with the two smaller terminals from the hardware bag. Plug the terminals into the circuit board. These connections are not polarity specific.

Note: If the room sensor is located too close to the appliance, or in a direct path of the distribu- tion air, You may need to elevate the temperature setting to maintain a comfortable temperature level throughout the heated space.

See Draft Test Procedure on Page 26.

Save These Instructions