Harman Stove Company P35I E. Existing Fireplace, Rear Vent, Vent pipe seams must be accessible

Models: P35I

1 48
Download 48 pages 52.68 Kb
Page 16
Image 16
E. Existing Fireplace, Rear Vent:
Zero Clearance Cabinet shown with Flue Rough-in Support

P35i Fireplace Insert

E. Existing Fireplace, Rear Vent:

The top of the chimney must also be sealed. Otherwise, it can become a nesting area or a water trap.

NOTE: When installed in a rear vent configuration, the maximum BTU may be reduced due to elevated ESP temperatures associated with the horizontal exhaust stream.

F.Optional Zero Clearance Cabinet Installation:

If passing through combustible material, the proper thimble from the vent manufacturer must be used.

wallMasonry

If installing using the optional zero clearance cabinet, Item #1-00-774257,the venting will need to exit through the top of the cabinet. The vent can be vertical or horizontal after leaving the cabinet. Once clear of the cabinet, a 90 degree elbow can be installed for rear termination as shown. Do not allow vent pipe seams to fall within the cabinet wall. Use proper wall thimble as supplied by the venting manufacturer.

If finishing the interior with stone or masonry, the venting can be installed without the appliance. Install the cabinet and secure the venting using the Flue Rough-in Support #1-00-774283.

Notice the side edges of the surround contain slotted openings. These openings allow room air to be drawn into the rear of the cabinet and circulated through the heat exchange and back into the room. These openings can not be blocked. If finishing with stone or

masonry keep the masonry a minimum of one inch from the sides of the surround. Mortar can be used to give a more finished look.

used in a constructed chase

to combustibles are met.

Vertical Venting may be

providing all clearances

 

 

Proper wall pass-thru device as recommended by the venting manufacturer.

F.Optional Zero Clearance Cabinet Installation:Vent pipe seams must be accessible. 3" Clearance

Vent pipe seams must be accessible.

16 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

Page 16
Image 16
Harman Stove Company P35I owner manual E. Existing Fireplace, Rear Vent, F.Optional Zero Clearance Cabinet Installation