QuickSpecs
HP Compaq 8100 Elite PC
Technical Specifications
| Small Form Factor | Convertible Minitower |
Dimensions |
|
|
Chassis | 3.95 x 13.30 x 14.9 in | 17.63 x 7.00 x 17.5 in |
(H x W x D) | 100 x 338 x 378.5 mm | 447.8 x 177.8 x 444.5 mm |
System Volume | 790.26 cu in | 2160 cu in |
| 12.95 L | 35.4 L |
Tower Stand | 1.12 x 7.01 x 7.87 in | N/A |
(H x W x D) | 28.5 x 178 x 200 mm |
|
Packaging | 9.00 x 19.68 x 23.38 in | 22.64 x 12.72 x 24.41 in |
(H x W x D) | 228.6 x 499.9 x 593.85 mm | 575.0 x 323 x 620 mm |
System Weight* | 16.72 lbs | 24.54 lbs |
| 7.6 kg | 11.15 kg |
Shipping Weight* | 17.86 lbs | 34.0 lbs |
| 8.1 kg | 15.42 kg |
Max Supported Weight | 77 lb | 77 lbs |
(desktop orientation) | 35 kg | 35 kg |
*Configured with 1 hard drive, 1 optical drive, no diskette drive, and no PCI card.
Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow. Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re- circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.
Temperature Range | Operating: 50° to 95° F (10° to 35° C)* |
| |
Relative Humidity | Operating: 10% to 90% |
| |
Maximum Altitude | Operating: 10,000 ft (3048 m) |
(unpressurized) |
*Operating temperature is
DA - 13524 Worldwide — Version 5 — February 3, 2010 | Page 17 |