Christie Digital Systems LWU420 When authentication error occurred, Data Length, Check Sum

Page 13

Command Control via the Network (continued)

Decreasing the projector setting value (Decrement command)

(1)The PC sends the following decrement code to the projector.

Header + Command data (‘05H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)

(2)The projector decreases the setting value on the above setting code.

(3)The projector returns the response code ‘06H’ to the PC.

When the projector cannot understand the received command

When the projector cannot understand the received command, the error code ‘15H’ is sent back to the PC.

Sometimes the projector cannot properly receive the command. In such a case, the command is not executed and the error code ‘15H’ is sent back to the PC. If this error code is returned, send the same command again.

When the projector cannot execute the received command.

When the projector cannot execute the received command, the error code ‘1CH’ + ‘xxxxH’ is sent back to the PC.

When the data length is greater than indicated by the data length code, the projector ignore the excess data code. Conversely when the data length is shorter than indicated by the data length code, an error code will be returned to the PC.

When authentication error occurred.

When authentication error occurred, the error code the ‘1FH’ + ‘0400H’ is sent back to the PC.

NOTE • Operation cannot be guaranteed when the projector receives an undefined command or data.

Provide an interval of at least 40ms between the response code and any other code.

Commands are not accepted during warm-up.

[TCP #9715]

1. Protocol

Consist of header (1 byte) + data length (1 byte) + command data (13 bytes) + check sum (1 bytes) + connection ID (1 byte).

2.Header

02, Fixed

3.Data Length

Network control commands byte length (0D, Fixed)

4. Command data

Network control commands that start with BE EF (13bytes).

5. Check Sum

This is the value to make zero on the addition of the lower 8 bits from the header to the checksum.

6. Connection ID

Random value from 0 to 255 (This value is attached to the reply data).

11

LWU420 User Manual-Technical Guide020-000320-01 Rev. 1 (06-2010)

Image 13
Contents LWU420 Page Example of computer signal Initial set signals RGB 2G/Y, B/CB/PB, R/CR/PR, H Connection to the portsComponent Video E Y, F CB/PB, G CR/PR Audio in 1, K Audio USB RS-232C Communication Command dataProtocol HeaderChanging the projector settings Set command Requesting projector status Get commandUsing the projector default settings Reset Command Increasing the projector setting value Increment commandCommand Control Settings Command Control via the NetworkCommunication Port Command Format TCP #23 Data Length When authentication error occurredCheck Sum Connection IDReply Data Automatic Connection BreakRS-232C Communication / Network command table Gamma Color Temp Be EF FE D7 Color Space Auto Keystone Active Iris Standby RGB2 Be EF EA F5 Turn OFF DA B6 Bass RGB1 Audio Component 日本語 Template MY BUTTON-1 Closed Caption