Christie Digital Systems LWU420 user manual Automatic Connection Break, Reply Data

Page 14

Command Control via the Network (continued)

7. Reply Data

The connection ID (the data is same as the connection ID data on the sending data format) is attached to the Network control commands reply data.

ACK reply: ‘06H’ + ‘xxH’

NAK reply: ‘15H’ + ‘xxH’

Error reply: ‘1CH’ + ‘xxxxH’ + ‘xxH’

Data reply: ‘1DH’ + ‘xxxxH’ + ‘xxH’

Projector busy reply: ‘1FH’ + ‘xxxxH’ + ‘xxH’

Authentication error reply: ‘1FH’ + ‘0400H’ + ‘xxH’

(‘xxH’ : connection ID)

Automatic Connection Break

The TCP connection will be automatically disconnected after there is no communication for 30 seconds after being established.

Authentication

The projector does not accept commands without authentication success when authentication is enabled. The projector uses a challenge response type authentication with an MD5 (Message Digest 5) algorithm. When the projector is using a LAN, a random 8 bytes will be returned if authentication is enabled. Bind this received 8 bytes and the authentication password and digest this data with the MD5 algorithm and add this in front of the commands to send.

Following is a sample if the authentication password is set to “password” and the random 8 bytes are “a572f60c”.

1)Select the projector.

2)Receive the random 8 bytes “a572f60c” from the projector.

3)Bind the random 8 bytes “a572f60c” and the authentication password “password” and it becomes “a572f60cpassword”.

4)Digest this bind “a572f60cpassword” with MD5 algorithm. It will be “e3d97429adffa11bce1f7275813d4bde”.

5)Add this “e3d97429adffa11bce1f7275813d4bde” in front of the commands and send the data.

Send “e3d97429adffa11bce1f7275813d4bde”+command.

6)When the sending data is correct, the command will be performed and the reply data will be returned. Otherwise, an authentication error will be returned.

NOTE • As for the transmission of the second or subsequent commands, the authentication data can be omitted when the same connection.

12

LWU420 User Manual-Technical Guide020-000320-01 Rev. 1 (06-2010)

Image 14
Contents LWU420 Page Example of computer signal Initial set signals Connection to the ports RGB 2G/Y, B/CB/PB, R/CR/PR, HComponent Video E Y, F CB/PB, G CR/PR Audio in 1, K Audio USB Protocol Command dataRS-232C Communication HeaderUsing the projector default settings Reset Command Requesting projector status Get commandChanging the projector settings Set command Increasing the projector setting value Increment commandCommunication Port Command Control via the NetworkCommand Control Settings Command Format TCP #23 Check Sum When authentication error occurredData Length Connection IDAutomatic Connection Break Reply DataRS-232C Communication / Network command table Gamma Color Temp Be EF FE D7 Color Space Auto Keystone Active Iris Standby RGB2 Be EF EA F5 Turn OFF DA B6 Bass RGB1 Audio Component 日本語 Template MY BUTTON-1 Closed Caption