Inverter Electrical Specification:
For Fujitsu FLC488SC8V-10  (AL1912 m)
  | Condition  | Min.  | Typ.  | Max.  | Unit  | |
  | 
  | 
  | 
  | 
  | 
  | |
Input Voltage  | 15  | V  | ||||
  | 
  | 
  | 
  | 
  | 
  | |
Input Current  | 1.5  | A  | ||||
  | 
  | 
  | 
  | 
  | 
  | |
Backlight ON/OFF Control  | ON  | 
  | 3.3  | 
  | V  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | OFF | 
  | 0  | 
  | V  | |
  | 
  | 
  | 
  | 
  | 
  | |
Brightness Adjust  | Min. Luminance / Max.  | 30%  | ||||
Luminance  | ||||||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
Output Voltage  | Vin=15V, Iout=6.5mA  | 750  | Vrms  | |||
  | 
  | 
  | 
  | 
  | 
  | |
Brightness  | lamp current in 6.5mA  | 250  | 300  | 
  | Cd/m²  | |
  | 
  | 
  | 
  | 
  | 
  | |
Output Current(Each connector)  | Vbri=0.4V~3.3V  | 4  | 7  | 8  | mA  | |
  | 
  | 
  | 
  | 
  | 
  | |
Frequency  | 40  | 50  | 60  | KHz  | ||
  | 
  | 
  | 
  | 
  | 
  | |
Lamp start voltage  | @0℃  | 1600  | Vrms  | |||
  | 
  | 
  | 
  | 
  | 
  | |
Striking Time  | 
  | 1  | S  | |||
  | 
  | 
  | 
  | 
  | 
  | |
Lamp Current Balance  | ±0.3  | mA  | ||||
  | 
  | 
  | 
  | 
  | 
  | |
Efficiency  | Vin=15V  | 80  | %  | |||
  | 
  | 
  | 
  | 
  | 
  | |
Operating Life Time  | 50000  | Hr  | ||||
  | 
  | 
  | 
  | 
  | 
  | 
*.The open lamp voltage is testes at output connector terminal
SAFETY
Leakage Current: 0.25mA @ 100Vac
Insulation Resistance: more than 3M ohms while withstanding a voltage of 500Vac
- 28 -