TROUBLESHOOTING (continued)
Indicators Message
The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.
Table 10. Indicators Message
POWER | LAMP | TEMP | Contents | |
indicator | indicator | indicator | ||
| ||||
|
|
|
| |
Lights | Turns off | Turns off | The Standby mode has been set. | |
orange | ||||
|
|
| ||
|
|
|
| |
Blinks | Turns off | Turns off | Warming up. Please wait. | |
green | ||||
|
|
| ||
|
|
|
| |
Lights | Turns off | Turns off | ON. Normal operation possible. | |
green | ||||
|
|
| ||
|
|
|
| |
Blinks | Turns off | Turns off | Cooling. Please wait. | |
orange | ||||
|
|
| ||
|
|
|
| |
|
|
| Cooling. Please wait. | |
Blinks red | - | - | The error is found. Take the appropriate measures when the | |
|
|
| POWER indicator ceases blinking | |
|
|
|
| |
|
|
| Lamp is not lit. | |
Blinks | Lights |
| The interior of the equipment may be too hot. Switch power OFF, | |
Turns off | wait 20 minutes until the equipment cools, and check whether the | |||
/Lights red | red |
| ventilation openings are blocked, whether the air filter is dirty, or | |
|
|
| whether the ambient temperature exceeds 35 °C. And switch | |
|
|
| power ON again. Replace the lamp if the same problem occurs. | |
|
|
|
| |
Blinks | Blinks |
| Lamp or lamp cover is not found, or hasn’t been fitted in correctly. | |
Turns off | Switch power OFF, and wait for 45 minutes until the equipment | |||
/Lights red | red |
| cools. Check fitting of the lamp and lamp cover, and switch power | |
|
|
| ON again. Contact BOXLIGHT if the same problem occurs again. | |
|
|
|
| |
Blinks |
| Blinks | The cooling fan is not operating. | |
Turns off | Switch power OFF, and wait for 20 minutes until the equipment | |||
/Lights red | red | cools. Check for foreign matters in the fan, and switch power ON | ||
|
|
| again. Contact BOXLIGHT if the same problem occurs again. | |
|
|
|
| |
|
|
| The interior of the equipment is too hot. | |
Blinks |
|
| Switch power OFF, and wait for 20 minutes until the equipment | |
Turns off | Lights red | cools. Check whether the ventilation openings are blocked, | ||
/Lights red |
|
| whether the air filter is dirty, or whether the ambient temperature | |
|
|
| exceeds 35 °C. Then switch power ON again. Contact BOXLIGHT | |
|
|
| if the same problem occurs again. | |
|
|
|
| |
Lights | Blinks | Blinks | The interior of the equipment is too cool. | |
Check whether the ambient temperature is below 0°C. Contact | ||||
green | red | red | BOXLIGHT if the same problem occurs when the ambient | |
|
|
| temperature is 0~35°C. | |
|
|
|
|
NOTE When the internal temperature becomes excessive power is switched OFF automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and wait for 20 minutes until the equipment has cooled sufficiently.