Maintenance
Lamp Information
Use and Replacement of the Lamp
When the Lamp Indicator lights up red or a message appears suggesting the time of lamp replacement, please install a new lamp or consult your dealer. An old lamp could cause a malfunction in the projector and in rare instances may even explode.
Lamp LED Indicators
Lamp Life Indicators | When the LED lights up red, it is warning you that lamp uage |
| has exceeded 2000 hours. Replace the projection lamp with a |
| new one immediately. |
|
|
The Lamp is not properly | LED lights up red. |
attached |
|
|
|
The temperature is too | When the projector’s internal temperature is too high for the |
high | projector to operate safely, the LED blinks orange and the |
| lamp turns off automatically. The LED keeps blinking while |
| the unit is off. |
| If the LED light is off, the operation and temperature of the |
| projector’s lamp are normal. |
|
|
The LAMP indicator will light up if the lamp becomes too hot. Turn off the power and let the projector cool for 45 minutes. If the LAMP indicator is still red when turning the power on, please contact your dealer.
Lamp Replacement
To reduce the risk of electrical shock, always turn off the projector and disconnect the power cord before changing the lamp.
To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes before replacing the lamp.
To reduce the risk of injuries to fingers and damage to internal components, use caution when removing lamp glass that has shattered into sharp pieces.
To reduce the risk of injuries to fingers and/or compromising image quality by touching the lens, do not touch the empty lamp compartment when the lamp is removed.
This lamp contains mercury. Consult your local hazardous waste regulations to dispose of this lamp in a proper manner.
Maintenance 23