Bosch Appliances LTC 5104 Dwell Time, Operating Mode LTC 5108 Series Only, Alarm Reset Mode

Page 10

LTC 5104, LTC 5108 Series Instruction Manual Installation

EN 10

 

 

To abort and resume normal operation, press

DWELL.

To reset to factory defaults, press SKIP/clr, moving the cursor to RESET, then press DWELL. This option also performs a VideoSearch.

NOTE: Resetting the unit to factory defaults will not reset the title characters to be blank.

4.8Dwell Time

This menu (see SCREEN 1) is used to program dwell times of 1 second to 64 seconds for the cameras. There are two modes of dwell that may be chosen; All Cameras and Individual Cameras. All Cameras mode sets the displayed dwell time for all four or eight cameras. Individual Cameras mode sets the displayed dwell time for only the camera number indicated on-screen. Upon entry into the Dwell Time menu, the dwell mode defaults to All Cameras. The Individual Cameras mode is entered using the numeric keys or the RUN/next key. RUN/next key selects individual camera dwell times by sequencing forward. Each numeric key selects that particular camera input. The video of the selected individual camera will be displayed (on the monitor for LTC 5104 Series, or on both monitors for the

LTC 5108 Series), provided the camera input has not been skipped. If a camera input is skipped, its dwell time menu can be entered but the unit will not switch video to that camera input. Since no dwell menu can be displayed if there is no video to that input, it is recommended to skip all camera inputs without video before attempting to set individual dwell times. Once in Individual mode, the Dwell Time menu must be exited and re-entered if All Cameras mode is desired. SKIP/clr decreases displayed dwell time, and ALARM increases dwell time. The default is All Cameras with a dwell of three seconds.

4.9Operating Mode

LTC 5108 Series Only

Two modes of operation can be selected for the

LTC 5108 Series switchers (see SCREEN 2). The two modes only affect Monitor B; Monitor A continuously sequences regardless of mode. In the Sequencing Mode, Monitor B will show either an alarm call up of a camera, a camera under a Hold condition, or normal sequencing of cameras. In the Blanking Mode, Monitor B will show either an alarm call up of a camera, a camera under a Hold condition, or a blank screen.

Operating Modes

Monitor A

 

Monitor B

 

 

Sequencing Mode

1. Normal sequencing of

1. Normal sequencing

camera inputs

 

(same as Monitor A)

 

 

 

 

2.

HOLD condition

 

 

 

 

3.

ALARM condition

 

 

Blanking Mode

 

 

 

1. Normal sequencing

1.

Blank screen

of camera inputs

 

 

 

 

 

 

2.

HOLD condition

 

 

 

 

3.

ALARM condition

 

 

 

4.10 Alarm Reset Mode

There are two Alarm Reset modes, AUTO and MANUAL (see SCREEN 4). In the AUTO reset mode, alarm call ups automatically reset after the Alarm Capture Time has expired. In the MANUAL reset mode, alarm call ups are held until manually reset via SKIP/clr. SKIP/clr toggles the selection pointer between the two modes. The default is AUTO.

Screen 4

Bosch Security Systems 7 April 2004

Image 10
Contents 8-Position Premium Sequential Switchers LTC 5104, LTC 5108 SeriesImportant Safeguards For Outdoor Product Safety PrecautionsFor Indoor Product For Rack-Mount ProductSécurité FCC & Ices InformationSicherheitshinweise Precauciones de SeguridadVeiligheidsmaatregelenSicurezza Table of Contents Unpacking ServiceInstallation DescriptionProgramming System Setup Alarm Inputs and OutputResetting to Default Programming Alarm Reset Mode Operating Mode LTC 5108 Series OnlyDwell Time Alarm Capture Time Alarm CaptureAlarm Dwell Time Alarm Contact ClosuresProgramming Camera Titles Status Line Screen Display PositionScreen Display Brightness and Background Operation Illustrations LTC 5104 SeriesLTC 5108 Series DVR or VCR Font Tables Bosch Security Systems 7 April Bosch Security Systems 7 April Bosch Security Systems GmbH