4.11 Alarm Capture

This menu item appears only if the Auto Alarm reset mode is selected (see SCREEN 5). When the Alarm Capture is ON, alarm call ups are held for at least the length of their Alarm Capture Time. After its Alarm Capture Time has expired, the alarm call up remains as long as its contact closure exists. When the Alarm Capture is OFF, alarm call ups are held only as long as its contact closure is detected. The default is ON.

4.13 Alarm Dwell Time

The Alarm Dwell Time determines how long each alarm call up is displayed during sequencing of multiple alarms (see SCREEN 7). Use SKIP/clr to decrease time and ALARM to increase time. Alarm Dwell Time can be set from 1 second to 64 seconds. The default time is two seconds.

Screen 7

Screen 5

4.12 Alarm Capture Time

This menu item appears only when the Alarm Capture is ON (see SCREEN 6). The Capture Time specifies the minimum length of time that the alarm call up will be held, once its contact closure is detected. During multiple alarms, the Capture Time expires only while the alarm is being displayed. Use SKIP/clr to decrease time and ALARM to increase time. Alarm capture time can be set from 1 second to 63 seconds. The default time is 14 seconds.

Screen 6

4.14 Alarm Contact Closures

This screen enables the user to set alarm contact closures as NORMALLY OPEN or NORMALLY CLOSED. Press SKIP/clr to choose between the two options. The default is NORMALLY OPEN (see SCREEN 8).

Screen 8

Bosch Security Systems 7 April 2004

Image 11
Contents LTC 5104, LTC 5108 Series 8-Position Premium Sequential SwitchersImportant Safeguards For Rack-Mount Product Safety PrecautionsFor Indoor Product For Outdoor ProductFCC & Ices Information SécuritéPrecauciones de Seguridad SicherheitshinweiseVeiligheidsmaatregelenSicurezza Table of Contents Description ServiceInstallation UnpackingResetting to Default Programming Alarm Inputs and OutputProgramming System Setup Dwell Time Operating Mode LTC 5108 Series OnlyAlarm Reset Mode Alarm Contact Closures Alarm CaptureAlarm Dwell Time Alarm Capture TimeScreen Display Brightness and Background Status Line Screen Display PositionProgramming Camera Titles Operation LTC 5104 Series IllustrationsLTC 5108 Series DVR or VCR Font Tables Bosch Security Systems 7 April Bosch Security Systems 7 April Bosch Security Systems GmbH