Ch4. Symptom-to-part index
Error message
Symptom / Error |
| FRU or action, in sequence |
|
| |
Device address conflict. | 1. Load Setup Defaults in BIOS Setup Utility. | |
| 2. | Backup battery. |
| 3. | System board. |
|
| |
Allocation error for device. | 1. Load Setup Defaults in BIOS Setup Utility. | |
| 2. | Backup battery. |
| 3. | System board. |
|
| |
Failing bits: nnnn. | 1. DIMM. | |
| 2. | System board. |
|
| |
Invalid System Configuration Data. | 1. DIMM. | |
| 2. | System board. |
|
| |
I/O Device IRQ Conflict. | 1. Load Setup Defaults in BIOS Setup Utility. | |
| 2. | Backup battery. |
| 3. | System board. |
|
| |
Operating System not found. | 1. Check that the operating system has no failure and | |
|
| is installed correctly. |
| 2. | Enter BIOS Setup Utility and see whether the hard |
|
| |
|
| identified. |
| 3. | Reset the |
| 4. | Reinstall the operating system. |
| 5. | Diskette drive. |
| 6. | |
| 7. | System board. |
|
| |
Hibernation error. | 1. Restore the system configuration to what it was | |
|
| before the computer entered hibernation mode. |
| 2. | If memory size has been changed, |
|
| hibernation file. |
|
| |
FAN error. | Fan. | |
|
| |
Thermal sensing error. | System board. | |
|
|
|
47