Indicators
The projector has three LED Indicators which shows the working condition of the projector.
The following offers solutions to possible problems. If a problem persists, turn the projector off and consult your dealer.
POWER indicator
LAMP indicator
TEMP indicator
| AUTO POSITION |
POWER | MUTE |
| COMPUTER |
LAMP | SOURCE |
VOLUME | VIDEO |
TEMP | MENU |
| ENTER |
Normal condition
POWER LAMP | TEMP CONDITION | Notes | |
Steady | Off |
| |
Off |
| ||
red |
|
|
|
|
| Lamp | The power button cannot be used to switch |
Steady | Blinking | Off | ON and OFF |
green | green |
| |
|
| The POWER is ON. (Normal condition) |
|
Steady | Steady | Off |
|
green | green |
|
|
Abnormal condition
POWER LAMP TEMP CONDITION | POSSIBLE SOLUTIONS |
Steady | Steady | Blinking | Unusual temperature | |
• | The ventilation slits or air filter is clogged with | |||
green | green | red |
| dust or debris. |
|
|
|
| |
|
|
| • | The fan has stopped due to an impediment. |
Steady | Off | Blinking | • | The room temperature is too high. |
red |
| red | • The filter is dirty. | |
|
|
|
Lamp duration warning. (Lightning duration total
Steady Blinking Off about 1, 500 hours.When the POWER is ON.)
green green/red
Steady | Blinking | Off | Lamp duration warning. (Lightning duration total | |
about 1, 500 hours.When the POWER is OFF.) | ||||
red | red |
|
•Remove the object from the ventilation slits.
•Pull out the power plug andremove the object. If you cannot, consult your dealer.
•Relocate the projector to a cooler place.
•Clean the filter.
Replace the lamp.
Exchange with a new lamp if the same problem recurs.
Steady | Steady | Off | Lamp duration warning. (Lightning duration total |
|
about 2,000 hours.) |
| |||
red | red |
|
| |
|
|
| The lamp or filter cover is not closed. | Close the cover correctly. |
Blinking | Off | Off |
|
|
green/red |
|
|
|
|
| Steady | Steady | Abnormal. | Contact your dealer. |
|
|
| ||
Blinking | or | or |
|
|
|
|
|
| |
green/red |
|
|
|
|
| Blinking | Blinking |
|
|
EN – 26