Troubleshooting

Before asking for repair of the projector, check the following. If the symptom persists, stop using the projector, be sure to unplug the power plug, and then contact your dealer.

No image appears on the screen.

Problem

Solution

 

 

Check whether the indicators are on or off and how they are lightning.

POWER

STATUS Solution

Off

Off

Steady green

Blinking

green

 

Steady amber Steady green

Power can not be turned on.

 

Steady green

Blinking

red

Blinking

Off

green

 

Blinking

Blinking

green

red

 

• Cancel the AV mute by pressing the AV MUTE button.

 

• Check that the lens cap is removed.

 

• It may take about 1 minute for the lamp to light up.

 

• The lamp fails to light up on rare occasions. In such a case, wait for a few minutes and then try again.

 

• If the projector was turned off before the lamp was cooled down sufficiently last time, the fan may start rotat-

 

ing and the ON button may not work after the power cord is plugged. After the fan stops rotating, press the

No image appears on the screen.

ON button to turn back on the POWER indicator.

• Check that the intake vent is clean.

 

 

• Check that the lamp cover is closed.(See page 20.)

 

• Check that the cables connected to the external devices are not broken.

 

• When an extension cable is being used, replace it with the supplied cable for check.

 

• When images are displayed correctly, add an RGB signal amplifier to the extension cable.

 

• When the menu is turned on and the signal is lost or not input, the system will not search for the signal even

 

if the signal is input again. In this case, turn off the menu.

 

 

 

• This problem may occur when the intake vent and/or exhaust vents are blocked. (For example: the STATUS

 

indicator brinks red.)

 

J Remove the objects blocking the intake vent and/or exhaust vents and then carry out the following proce-

 

dure.

 

1. Wait for the intake fan and/or exhaust fan to stop. (Wait until the POWER indicator lights green.)

 

2. Unplug the power cord from the wall outlet.

Power turns off.

3. Wait about 10 minutes.

 

4. Plug the power cord into the wall outlet.

 

5. Press the ON button.

 

• When the POWER indicator is steady amber, it is indicating that the lamp should be replaced. Replace the

 

lamp in this case.

 

• If the lamp has deteriorated, it may go out after a while it illuminates.

 

• Check if the "Auto power off" function is set.

 

 

 

• Turn on the power of the connected device, or check whether there is something wrong with the connected

 

device.

 

• Check whether the external device output signals. (Check this especially when the external device is a note-

 

book computer.)

"No Signal" is displayed.

• Check that the cable connected to the external device isn’t defective.

 

• Check that the projector is connected to the external device using the correct terminals.

 

• Check that the connected device is correctly selected as the input source.

 

• When an extension cord is being used, replace it with the supplied cable and check whether images are pro-

 

jected correctly. If images are projected correctly, use an RGB signal amplifier along with the extension cord.

ENGLISH

EN-21

Image 21
Contents XD211U Shock When using the projector in EuropeContents Important safeguards Do not look into the lens when the projector is operating Do not keep using the damaged projectorDo not unplug the power cord during operation Place of installationOverview IndicatorTerminal board Kensington LockOverview Remote controlBottom side Cap RC lock buttonRemote control Operation range of the remote controlReception angle vertical Layout of the projector InstallationFront projection Front projection, ceiling mountingBasic connections Projector + AV deviceProjector + DVD player or Hdtv decoder Projector + Computer Basic connectionsUsing the adjustment feet front Adjustment of the projection anglePreparation Preparation for projectionPower-on When fine streaks are seen on projected imagesBasic operation Basic operation Menu operation Basic operation Menu operationMenu Options Picture menuComputer Image menu Simple adjustment methodVideo Image menu Sound menuSetting menu Factory Default menuLanguage menu Image adjustment Lamp replacement Interval of lamp replacementReset of the lamp operation time No image appears on the screen TroubleshootingImages are not displayed correctly TroubleshootingCleaning of the projector and the ventilation slots MaintenanceCleaning of the lens OthersIndicators Normal conditionAbnormal condition Specifications Connectors SpecificationsDimensional drawings unit mm What’s included in the boxVGA Mitsubishi Electric Corporation