Mitsubishi Electronics HC900E manual To set Tint at 0, enter +00. -00 is invalid

Page 5

How to set the grade

Use the ASCII codes to set the grade for setting data. Please refer to the table below for the HEX code.

ASCII

'+'

'–'

'0'

'1'

'2'

'3'

'4'

'5'

'6'

'7'

'8'

'9'

HEX

2Bh

2Dh

30h

31h

32h

33h

34h

35h

36h

37h

38h

39h

[Example 1] When setting the AUTO POWER ON to ON. (Figures and symbols enclosed in quotation marks are ASCII codes.):

Sending commands

Status code from

Description

from the PC, etc.

the projector

 

30 30 41 50 4F 4E 31 0D

 

Command for setting the

'0' '0' 'A' 'P' 'O' 'N' '1' ' '

 

AUTO POWER ON to ON

 

 

 

 

30 30 41 50 4F 4E 31 0D

Command receipt confirmation

 

'0' '0' 'A' 'P' 'O' 'N' '1' ' '

(Command echo back)

 

 

 

The data code of BRIGHTNESS consists of the difference data between R and G, the main data, and the difference data between B and G.

[Example 2] When setting the difference data between R and G to +10, the main data to 0, and the difference data between B and G to -5. (Figures and symbols enclosed in quotation marks are ASCII codes.):

Sending commands

 

Status code from

Description

from the PC, etc.

 

the projector

 

30 30 50 2B 31 30 2B 30 30 2D 30 35 0D

 

Command for setting the

'0' '0' 'Q' '+' '1' '0' '+' '0' '0' '-' '0' '5' '

'

 

picture control

 

 

 

 

 

 

30 30 50 2B 31 30 2B 30 30 2D 30 35 0D

Command receipt confirmation

 

 

'0' '0' 'Q' '+' '1' '0' '+' '0' '0' '-' '0' '5' ' '

(Command echo back)

 

 

 

 

[Example 3] When checking the TINT setting (when the TINT is set to +10). (Figures and symbols enclosed in quotation marks are ASCII codes.)::

Sending commands

Status code from

Description

from the PC, etc.

the projector

 

30 30 53 0D

 

Command for checking

'0' '0' 'S' ' '

 

the TINT setting

 

 

 

 

30 30 53 2B 31 30 0D

Check result (+10)

 

'0' '0' 'S' '+' '1' '0' ' '

 

 

 

 

• To set TINT at 0, enter +00. (-00 is invalid.)

5

Image 5
Contents Interface Control command diagramPC-controllable functions ConnectionControl sequence How to set the gradePassword lock commands Reading command diagram To set Tint at 0, enter +00. -00 is invalid