Mitsubishi Electronics LVP-SA51U user manual Lamp replacement, Interval of the lamp replacement

Page 22
Screw of the lamp lid
(a)
(b)

Lamp replacement

The lamp is designed to project the image on the LCD panels. When the lamp no longer functions, replace it with a new one.

Caution:

7. Put the handle back to the holding point.

Make sure that the handle is locked.

8.Tighten up the screws (a)

• Do not remove the lamp immediately after turning

off the lamp of the projector, you may get burned

because of the high temperature of the lamp.

using a phillips screwdriver

(+).

(a)

• For lamp replacement, press the power button to

power off, then wait for 60 seconds in stand-by mode

to allow the lamp and LCD panels to cool. Then turn

off the main switch, unplug the power cord from

the outlet, and wait one hour so that the lamp is

cooled to the touch.

• Do not remove the lamp except for replacement.

Careless treatment can cause injury or fire.

• Do not touch the lamp element directly. It may break

and cause you to injure or burn yourself.

• Be sure not to drop the lamp lid screw into the pro-

jector. Also be sure not to insert metal or any flam-

mable objects, it may cause fire or electric shock. If

any objects are inserted, please unplug and contact

your dealer.

• Install the lamp securely, failure may cause a fire.

1.Reverse the projector gently.

2.Loosen the screws of the lamp lid on the top cover using a phillips screw-

driver (+) , and remove the lid.

Remove the lamp cover in the direction of the arrow as indicated.

3. Loosen screws (a) using a phillips screwdriver (+).

4. Pull up the handle.

5. Hold onto the projector by the handle as you pull out the lamp.

Pull out the lamp straight upward.

• Once the lamp has been re- moved, do not spill liquid on it, place it near flam- mable objects or where children can touch it. Otherwise, it will cause injury or fire.

6. Insert the new lamp se- curely into the projector body in the right direc- tion.

Make sure that the two positioning bosses (b) fit to the lamp positioning holes before inseting the lamp.

9. Tighten up the screws of the lamp lid using a phillips screwdriver (+).

How to reset the operation time meter

Plug in the power cord, switch on the projector, and reset lamp time by pressing the $, % and POWER buttons simultaneously.

Caution:

Do not spill liquid on the lamp or place it near flam- mable objects or where children can touch it. Oth- erwise, it could cause injury or fire.

Be sure that the projector guide is firmly inserted between the right and left lamp guides.

Important:

The projector will not turn on if you do not secure the lamp lid.

You must reset the operation time meter after you replace the lamp.

Do not reset the operation time meter unless the lamp has been replaced.

Interval of the lamp replacement

The interval of the lamp replacement about 2,000 hours of consecutive use. Replacement span may differ ac- cording to operating environment, and may be shorter than 2,000 hours. Decreases in luminescence and/or color brightness will indicate that the light source lamp needs to be replaced. When lamp operation time ex- ceeds 1,500 hours, the indicator will flash alternately between green and red (while the lamp is in operation; when the lamp is not in operation, the indicator will appear red only). When the lamp has been used for about 1,900 hours, the message “LAMP!!.” will appear on the screen for one minute. When the lamp has been used for about 2,000 hours, the projector will automati- cally shut off for safety and the power indicator light will be red. The projector cannot be used until the lamp has been replaced and operation timer has been reset.

Caution:

The lamp is fragile. If broken, be careful not to cut yourself with glass fragments.

The replacement span of the lamp depends on the environment. For replacement lamps, please con- tact your dealer.

The projector automatically shuts off when the lamp is used up in about 2,000 hours and cannot be used until the lamp is replaced and the inter- nal timer is reset.

EN – 22

Image 22
Contents SA51 When using the projector in Europe Compliance NoticeContents Important safeguards Never remove the cabinet Do not look into the lens when it is operatingClean the air-filter once a month Do not modify this equipmentOverview Bottom side Remote control Battery installation Using the remote controlOperation area Screen InstallationOrientation of the projector Front projectionProjector + AV equipment Basic connectionsProjector + DVD player or Hdtv decoder For using Macintosh Projector + Personal computerPreparing the projector for operation Adjusting the angle of projectionGetting ready for projection To operate projector power on ConditionSound from the speaker Volume from the speakerTurning off the projector AV muteBasic operation Menu operationPress the Enter button or button When the source is selected to Video . Select Inputted to audio input terminal only when the source isSelected to COMPUTER. Select 2 Video mode to output Parmanent mode to output the sound which isUser memory for signal setting Color temperature Picture adjustmentAdjusting the image Color matrixAdjustment from personal computer Picture adjustment Using the Expand mode Advanced features for presentationSetting the Expand mode ExpandInterval of the lamp replacement Lamp replacementHow to reset the operation time meter Cleaning the projector and the ventilation grill MaintenanceCleaning the air-filter Cleaning the lensTroubleshooting Unusual temperature IndicatorsPower indicator Lamp indicator Temp indicator Normal conditionSpecifications Replacement part Option / Not included in the box ConnectorsDimensional drawings mm What’s included in the boxControl command diagram Control projector by using a personal computerInterface How to set the grade Operation commandsVolume commands Control sequenceMenu setting commands Remote commandsReading command diagram Example Display Menu selection bar. is for Ascii codeExample 1 Set the Auto Power on to on