Mitsubishi Electronics MAM-GM24, MAM-AM6, MAM-GM20 General Data, Tab -7General data, Feature Data

Page 38

Technical data of the MAM series

Appendix

 

 

 

 

 

General Data

 

 

 

 

 

 

 

 

Feature

 

Data

 

Power supply

 

10 – 30 V DC, max. 0.7 A, screw terminal 2.5 mm² und power supply jack

 

 

(pin diameter 2 mm, inner diameter 6 mm).

 

 

 

 

 

 

 

 

 

 

LEDs

 

Power, Process, Line (connection), Data out, Modem Mode

 

 

 

 

 

Operating elements

Button

 

 

 

 

 

 

Housing/mounting

DIN-Rail Casing, for rail 35mm to EN50022,

 

vertical or horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

, EN 55022 (9:2003), EN 55024 (10:2003) EN 301489-1/7 (2000 GSM)

 

 

 

GM series

EN 60950

 

 

 

 

 

 

Conformity

 

 

3GPP TS 51.010-1 (9:2002, v5.0.0.0) GCF-CC (10:2002, v3.8.1)

 

 

 

AM series

, EN 55022 (9:2003), EN 55024 (10:2003), EN 60950

 

 

 

 

 

 

 

R&TTE-Policy TS 103021

 

 

 

 

 

 

 

 

 

Temperature

Operation

0 ... +50 °C

 

range

 

Storage

-30 ... +70 °C

 

 

 

 

 

 

 

 

 

Permissible

 

5 to 95 % relative humidity, non-condensing

 

air humidity

 

 

 

 

 

 

 

 

 

Degree of protection

IP20

 

 

 

 

 

Degree of pollution

Pollution degree 2

 

 

 

 

 

 

Dimensions

 

Width: 88 mm x Height: 57 mm x Depth: 91 mm (without antenna connection)

 

 

 

 

 

 

Weight

 

240g

 

 

 

 

 

Tab. 10-7:General data

10 - 3

MITSUBISHI ELECTRIC

Image 38
Contents Draft Page About this Manual Page Alarm Modems AM and GM series Art-NoMitsubishi Electric Intended Target Audience Security AdviceSafety instructions Proper useMitsubishi Electric Function overview Mitsubishi Alarm Modems at a GlanceInstallation and Mounting InterfacesCommunication with a PLC Power supply Operation Configuration and projectsSoftware AppendixState-Of-The-Art Communication Mitsubishi Alarm Modems at a GlanceCommunicating possibilities with the Mitsubishi Alarm Modem Easy To RetrofitFunction overview Alarming with acknowledgmentRemote switching via SMS and Express-E-Mail Integrated PLC protocolsSecure Login Teleservice via PCPump alarm application example Pump alarmAlarm Modem GSM Installation and MountingOverview of the Connectors Tab -1Description of the connectors of the Alarm Modem GSMDescription of the connectors of the Alarm Modem 56k Alarm Modem 56kOverview of all connectors of the Alarm Modem 56k RS 485/422 with MAM-AM24Meaning of the LEDs Tab -3Meaning and function of the LEDsMounting Modem mounted on the DIN railConnecting the GSM antenna only GM series Inserting the SIM card only GM series Push down the button until the card holder is releasedMitsubishi Alarm Modem supports the a/b leads 3 Testing the Telephone ConnectionClip Feature Connection to the Telephone Network only AM seriesCOM2 RS232 Plug InterfacesCOM1 RS232 Jack Alpha XL Mitsubishi Alpha XL and Mitsubishi FX at RS232RS485 / RS422 Mitsubishi FX1S, FX1N, FX2N, and FX2NCAccess to the DIP switches 6Position of the DIP switches under the terminal coverRS485 2-wire connection 2-wire bus system, half-duplex Setting the operating mode on the DIP switchTab -1Setting the operating mode on the DIP switch Operating modeRS485 4-wire connection 4-wire bus system, full-duplex Mitsubishi FX at RS485/422Power supply Ensure that the screws are seated correctlyMemory test Self-test after power upOperation Tab -1LEDs during the self-testMitsubishi Alarm Modem is operational Line-LED when functioning correctly only GM seriesLoading projects in the MAM Configuration and projectsInitial configuration Loading projects remotely on the MAMPIN OK, no network, MAM not logged SIM card disabled, entry of the Super PINSIM Card Service Center PIN incorrect, MAM not loggedUsing MAM without MX-MAE Operating modes Modem Mode and TiXML ModeAlarm Editor MX-MAE activates the correct mode TiXML ModeActivating Modem Mode Activating/deactivating Modem ModeSending commands to the MAM Deactivating Modem Mode, activating TiXML ModeSoftware MX Mitsubishi Alarm Editor MX-MAESecure Login Access Protection Remote Access PLC driver in the Mitsubishi Alarm Modem Communication with a PLCMain functions Technical data of the MAM seriesAppendix System architectureFirmware Technical specifications GM seriesTechnical specifications AM series Serial interfacesTab -7General data Feature DataGeneral Data Factory Reset LEDs, Reset, Update, Error DiagnosticsLEDs in the event of faults only GM series LEDs on restartTab -11LEDs during Factory Reset and restart Firmware-UpdateLEDs during factory reset and restart Tab -10LEDs during Firmware-UpdateMobile networks in Europe USA worldwide AccessoriesAccessories Description Pin assignmentDimensions GM seriesService Power AM seriesMAM-GMx Mitsubishi Alarm Modems GSM with RS232 and RS485 TerminalsMAM-AMx Mitsubishi Alarm Modems 56k with RS232 and RS485 MAM-AM6 MAM-AM20Index PLCIndex Mitsubishi Alarm Modem Headquarters