Mitsubishi Electronics MIM-A01, MIM-G01 manual RS 232-Transparent-Mode TransMode

Page 28

RS 232-Transparent-Mode (TransMode)

Configuration

 

 

6.4RS 232-Transparent-Mode (TransMode)

The section is only valid for the Mitsubishi Super Modem (MIM-A01).

The TransMode allows the remote control of a control unit (PLC) or another RS-232 device via a Mitsubishi Super Modem as if you were sitting near the device and connected locally via RS 232. All commands that you can give to this device via the local RS 232 interface can also be issued via TransMode from any telephone connection or via GSM modem.

Dial-in access can be password-protected.

An application of the TransMode command, for example, would be the control and configuration of a technical system that is connected to the Mitsubishi Super Modem via an RS232 interface.

To use the TransMode, do the following:

￿Configure the Mitsubishi Super Modem using the TransMode command

￿Connect your Mitsubishi Super Modem to the device you want to control remotely.

To do so you will need a null modem cable (usually plug-plug), for example, the "Blue Adapter".

￿Test the remote dial-in with a Mitsubishi Super Modem or another modem using a terminal program (dial-in of the Mitsubishi Super Modem).

￿The Login command for the selected Mitsubishi Super Modem must be entered

within 5 seconds of the modem connecting (see section 6.4.3). The RS 232 is then con- nected to both modems.

￿Control your remote device.

All data that you send from the PC to the local modem is transmitted over the telephone line to the Mitsubishi Super Modem AT and from this modem to the connected device via RS 232. You can operate the connected device as if you were directly sitting in front of it.

￿Close the connection by

hanging up by the caller modem

optional timeout in the Mitsubishi Super Modem when no more data is coming (default: 75 seconds)

6.4.1Time delays during modem transmissions

A remote connection and data conversion in both modems lead to delays in the runtime of data from PC to the control unit in comparison to a direct local connection via an RS 232 cable. Some configuration programs for control units expect a response within a few milliseconds. Errors can occur in these programs. Ask the manufacturer of these programs and control units how the timeout for the communication with the control unit can be increased to, for example, 500 ms.

6 - 6

MITSUBISHI ELECTRIC

Image 28
Contents Draft Page About this Manual Page Art-No Industrial Modems MIM-A01 and MIM-G0Version Changes / Additions / Corrections Mitsubishi Electric Security Advice Safety instructionsIntended Target Audience Proper useMitsubishi Electric Mounting and Installation Power supply OperationMitsubishi Industrial Modems at a glance Equipment VersionsTechnical Data ConfigurationAppendix Mitsubishi Normal Modem GSM MIM-G01 Mitsubishi Industrial Modems at a glanceMitsubishi Super Modem 56k MIM-A01 Teleservice via PC Equipment VersionsModem Typ Tab -1Mitsubishi Industrial Modems at a glanceMounting and Installation Interfaces and ConnectorsOverview of all connectors of the Normal Modem GSM Tab -2Description of the connectors of the modemsMeaning of the LEDs Tab -3Two LEDs are used to show the state of the modemInserting the SIM card Connecting the GSM antennaPush down the button until the card holder is released 027954 Tab -4Description of the connectors of the Modems Overview of all connectors of the Super Modems 56kSuper Modem 56k MIM-A01 Tab -5Five LEDs are used to show the state of the modem LineTesting the Telephone Connection Connection to the Telephone NetworkTelephone Exchange System Mitsubishi Super Modem 56k supports the a/b leads 3Mounting Power supply Operation MIM-G01MIM-A01 LEDs on MIM-A01Configuration Project SettingsMIM and Mitsubishi Alpha XL Options GSM and serial communicationGSM SMS Short Message Service SMS SettingSMS Service Center Function Block SMS sendRecipient PLC Connection Initialisation of a GSM ModemMIM for FX Remote Access MIM and Mitsubishi Melsec FXConnection to other Mitsubishi Products MIM-G01 and FX MessengerTime delays during modem transmissions RS 232-Transparent-Mode TransModeTransMode Command TransMode Login CommandAT+T SEND=TransMode ExampleLogin without parameters Login with password and parametersTechnical Data Main FeaturesTab System ArchitectureFirmware Tab -4 FirmwareGeneral Data Tab -5General DataDimensions MIM-G01MIM-A01 Super Modem 56kAT Commands MIM-G01 Important AT Commands+CSQ Signal Quality AppendixNumberx AlphaxTypex +ICF Data Format Format Parity+IFC Flow Control DCEbyDTE DTEbyDCEMode Format +COPS GSM NetworkStat +CMGS Send SMSOverview of AT-Commands Service CommandsTab -10 Service Commands V24-V35 CommandsTab -14 Network Tab -15 SecurityData Commands SMS CommandsPhonebook Fax Commands CLASS2 Fax Commands CLASS1Special AT Commands Overview of AT Commands AT Commands MIM-A01Tab -22Overview of AT Commands AT Command Descriptions +TFORMAT Sets the data format+TBAUD Set the baudrate Select Serial Port Flow ControlDial Command Command Mode EchoSwitch Hook Control Result Code Display Control+VCID Caller ID Settings Overview of S-RegistersStore Active Profile Tab -24Overview of S-RegistersMessage Commands Overview of the CommandsSetting General Message Parameters AT+T Send=AllSending a Fax AT+T Send=FaxSending an SMS Message AT+T Send=SMSSending an Express E-Mail AT+T Send=ExpressSender SubjectSending Internet E-Mail Smtp AT+T Send=EmailRetrieving Internet E-Mail POP3 AT+T Send=POP3Size of detected messages Size of messages receivedAT+TList Displaying Received Messages AT+T List = typeAT+T Delete Deleting a Stored Message AT+T Delete=NumberAT+T Read Reading a Stored Message AT+T Read=Number+T Read Number, type, time ParameterList Message ParameterListModem Commands AT+T Answer=OnOffAT+T Answer? AT+T Time=timeAT+T Time? AT+T Echo=OnOffAT+T Echo? AT+T Verbose=OnOffAT+T Mode=Mode AT+T HelpAT+T Erase AT+T RedialAT+T RedialDelay AT+T RedialDelay?AT+T DialRules=DialMethod,DialTone AT+T DialRules?AT+T Speaker=Volume AT+ T Speaker Adjusting the Modem Speaker VolumeAT+T Speaker? Index MIM G01 MIM-A01Page Headquarters

MIM-G01, MIM-A01 specifications

Mitsubishi Electronics has long been a frontrunner in the realm of advanced technology, particularly in the development and optimization of automation solutions. Two of their standout offerings in the field of air conditioning technology are the MIM-A01 and MIM-G01 systems, which cater to both residential and commercial applications.

The MIM-A01 is an indoor unit featuring a sleek design that blends seamlessly with modern interior aesthetics. This unit is engineered for energy efficiency, boasting an impressive seasonal energy efficiency ratio (SEER) that significantly reduces electricity consumption. One of its key features is the V-Flow design technology, which allows for enhanced airflow distribution, ensuring that every corner of the room receives adequate cooling or heating. The MIM-A01 also comes with advanced filtration systems, including a high-performance filter that captures dust and allergens, promoting a healthier indoor environment.

On the other hand, the MIM-G01 represents Mitsubishi's commitment to high-quality outdoor units. This model is known for its compact size and robust design, making it suitable for a variety of installation spaces. With its advanced inverter technology, the MIM-G01 can adjust its cooling or heating output according to the changing conditions, thereby optimizing energy usage. One of its hallmark technologies is the Hyper Heating feature, which allows the unit to maintain its performance even at extremely low outdoor temperatures, making it ideal for colder climates.

Both units share a common thread of smart technology integration. They are equipped with wireless control capabilities, allowing users to adjust settings remotely via smartphone apps or smart home systems. This feature not only enhances user convenience but also facilitates better energy management by allowing users to monitor and control energy use from anywhere.

In summary, the Mitsubishi Electronics MIM-A01 and MIM-G01 systems epitomize modern air conditioning technology with their focus on energy efficiency, innovative airflow design, and advanced smart features. Whether for a small residential space or a larger commercial application, these units align with the evolving demands of energy-conscious consumers while delivering optimal performance and comfort. Their commitment to quality and advanced technology solidifies Mitsubishi's position as a leader in the HVAC industry.