b. UDP header:

i.Source Port number = “UDP Port” in the “This Unit” portion in the configuration panel.

ii.Destination Port number = “UDP Port” in the “Dest. Unit” portion in the configuration panel.

iii.UDP Length = UDP header length + data length. This data length would be =< “Max Bytes/Pkt” value.

iv.The “Max Bytes/Pkt” field is in the “Configuration Panel.” (See section II for detail).

v.UDP Check sum = calculated over UDP header and serial data. c. RS232 Data: this is the serial data received from serial port.

Incoming UDP/IP packet:

a.IP Header: checking on the following fields. Other fields that are not mentioned are not checked.

i.Total length: must be greater than IP header length and UDP header length

ii.Flags and Fragment offset: must be “Don’t fragment” and “Last fragment”

iii.Protocol: must be UDP.

iv.IP Header check sum: must be correct

v.Source IP address: must be equal “IP Addr” in the “Dest. Unit” portion in the configuration panel.

vi.Destination IP address: must be equal “IP Addr” in the “This Unit” portion in the configuration panel.

b.UDP header: checking on the following fields. Other fields that are not mentioned are not checked.

i.Source Port number: must be equal “UDP Port” in the “Dest. Unit” portion in the configuration panel.

ii.Destination Port number: must be equal “UDP Port” in the “This Unit” in the configuration panel.

iii.UDP Length = UDP header length + data length. The data length has to be =< 200.

iv.UDP Check sum: ignored if 0. Otherwise, a checksum calculation is performed on UDP header and serial data.

16

Image 19
Contents 802.11b Wireless Serial Port Adapter WiSER2400.IP User Guide Page Table of Content Introduction Introduction Key Features WiSER2400.IP WiFi RadioPower Installation of WiSER2400.IPRS232 Connection Link Yellow Status LED’sPage Installation Installation of WiSER2400.IP Software System RequirementsOverview Diagnostic and Configuration UtilityRadio Status Panel Connection and Overall Status PanelConfiguration Panel Configuration PanelPage RS232 Statistics RS232 and Wlan Statistics PanelWlan Statistics Encryption sub-panel Security PanelWEP Keys Creation Sub-panel Create WEP Keys with Manual Entries Page Learning the destination MAC address from ARP packets UDP/IP ImplementationOutgoing UDP/IP packet IP Header Incoming UDP/IP packet UDP headerNo Data Transfer While the Radio Link is Good TroubleshootingBlank Pages Appear When Open the Utility Program No Radio LinkRadio Interference Poor Link QualityTechnical Support WiSER2400 Software Appendix a Limited Warranty WiSER2400 HardwareFCC Radiation Exposure Statement FCC ID MKZ0207232XG FCC Rules and Regulations PartPage Glossary