Online/activity LED | Fault/UID LED | Interpretation |
(green) | (amber/blue) |
|
|
|
|
On, off, or flashing | Steadily blue | The drive is operating normally, and it has been selected by a |
|
| management application. |
|
|
|
On | Amber, flashing | A predictive failure alert has been received for this drive. |
| regularly (1 Hz) | Replace the drive as soon as possible. |
|
| |
|
|
|
On | Off | The drive is online, but it is not active currently. |
|
|
|
Flashing regularly | Amber, flashing | Do not remove the drive. Removing a drive may |
(1 Hz) | regularly (1 Hz) | terminate the current operation and cause data loss. |
|
| The drive is part of an array that is undergoing capacity |
|
| expansion or stripe migration, but a predictive failure alert has |
|
| been received for this drive. To minimize the risk of data loss, do |
|
| not replace the drive until the expansion or migration is |
|
| complete. |
|
|
|
Flashing regularly | Off | Do not remove the drive. Removing a drive may |
(1 Hz) |
| terminate the current operation and cause data loss. |
|
| The drive is rebuilding, or it is part of an array that is undergoing |
|
| capacity expansion or stripe migration. |
Flashing irregularly | Amber, flashing | The drive is active, but a predictive failure alert has been |
| regularly (1 Hz) | received for this drive. Replace the drive as soon as possible. |
|
|
|
Flashing irregularly | Off | The drive is active, and it is operating normally. |
|
|
|
Off | Steadily amber | A critical fault condition has been identified for this drive, and |
|
| the controller has placed it offline. Replace the drive as soon as |
|
| possible. |
Off | Amber, flashing | A predictive failure alert has been received for this drive. |
| regularly (1 Hz) | Replace the drive as soon as possible. |
|
|
|
Off | Off | The drive is offline, a spare, or not configured as part of an |
|
| array. |
|
|
|
Fans
Item
1
Description
System fan
Component identification 58