Pioneer ML310 manual Fans

Page 58

Online/activity LED

Fault/UID LED

Interpretation

(green)

(amber/blue)

 

 

 

 

On, off, or flashing

Steadily blue

The drive is operating normally, and it has been selected by a

 

 

management application.

 

 

 

On

Amber, flashing

A predictive failure alert has been received for this drive.

 

regularly (1 Hz)

Replace the drive as soon as possible.

 

 

 

 

 

On

Off

The drive is online, but it is not active currently.

 

 

 

Flashing regularly

Amber, flashing

Do not remove the drive. Removing a drive may

(1 Hz)

regularly (1 Hz)

terminate the current operation and cause data loss.

 

 

The drive is part of an array that is undergoing capacity

 

 

expansion or stripe migration, but a predictive failure alert has

 

 

been received for this drive. To minimize the risk of data loss, do

 

 

not replace the drive until the expansion or migration is

 

 

complete.

 

 

 

Flashing regularly

Off

Do not remove the drive. Removing a drive may

(1 Hz)

 

terminate the current operation and cause data loss.

 

 

The drive is rebuilding, or it is part of an array that is undergoing

 

 

capacity expansion or stripe migration.

Flashing irregularly

Amber, flashing

The drive is active, but a predictive failure alert has been

 

regularly (1 Hz)

received for this drive. Replace the drive as soon as possible.

 

 

 

Flashing irregularly

Off

The drive is active, and it is operating normally.

 

 

 

Off

Steadily amber

A critical fault condition has been identified for this drive, and

 

 

the controller has placed it offline. Replace the drive as soon as

 

 

possible.

Off

Amber, flashing

A predictive failure alert has been received for this drive.

 

regularly (1 Hz)

Replace the drive as soon as possible.

 

 

 

Off

Off

The drive is offline, a spare, or not configured as part of an

 

 

array.

 

 

 

Fans

Item

1

Description

System fan

Component identification 58

Image 58
Contents May 2006 Fourth Edition Part Number Audience assumptions Contents Acronyms and abbreviations Index Customer self repair Parts only warranty serviceRéparation par le client CSR Service de garantie pièces seules Riparazione da parte del clienteServizio di garanzia per i soli componenti Reparaciones del propio cliente Servicio de garantía exclusivo de componentes Reparo feito pelo cliente Garantieservice Parts OnlyServiço de garantia apenas para peças Customer self repair Customer self repair Customer self repair Customer self repair Illustrated parts catalog Mechanical componentsPage Page Illustrated parts catalog System components System componentsMass storage devices Page Illustrated parts catalog Safety considerations Removal and replacement proceduresRequired tools Server warnings and cautions Preparation procedures Power down the serverAccess panel Hot-plug Scsi hard drive Hot-plug SAS and Sata hard drivesNon-hot-plug hard drive cage Hard drive non-hot-plug Hot-plug SCSI, SAS, or Sata hard drive cage Hot-plug Scsi backplaneHot-plug SAS or Sata backplane Diskette drive CD-ROM/DVD-ROM drivePower supply Air baffleDimm Page Processor assembly Removal and replacement procedures PCI expansion board Fan assembly Power button/LED boardBattery System board Select the Advanced Options menu Cabling Hot-plug Scsi hard drive cablingNon-hot-plug Scsi hard drive cabling Hot-plug Sata hard drive cablingNon-hot-plug Sata hard drive cabling SAS hard drive cablingArray Diagnostic Utility HP Insight Diagnostics Diagnostic toolsSurvey Utility ROMPaq disaster recovery Integrated Management LogComponent identification Front panel componentsFront panel LEDs and buttons Rear panel components Rear panel LEDsSystem board components System maintenance switch System board LEDs System LEDs and internal health LED combinations Scsi IDs Hot-plug Scsi hard drive LEDs Hot-plug Scsi hard drive LED combinations LEDSAS and Sata hard drive LED combinations Fans Description Processor fan Component identification Server specifications SpecificationsEnvironmental specifications Dimensions CD-ROM drive specifications Hard drive specificationsDVD-ROM drive specifications Specification Value Stop time Single 30 s multisession Acronyms and abbreviations RAID Index Index