Environmental Specifications

Temperature

Operating: -20° to 60° C

Operating Survival: -25° to 65° C

Storage: -20° to +70° C

Humidity

Operating: 5 to 90% RH, 40° C, non-condensing

Non-operating:5 to 93% RH, non-condensing

Altitude

Operating: 10,000 ft (IEC 60068 PT2-13, 4 hours)

Non-operating:15,000 ft (IEC 60068 PT2-13, 4 hours)

Vibration

Operating (random): 10 to 500 Hz, 3.0 G rms acceleration, 3 hours per axis

Shock

Operating/Non-operating:50 G, 11 ms duration, 1/2 sine, 3 shocks per axis (IEC 60068 PT2-27)

Connectors

J1: Video Input

15-pin D-Sub VGA, female, Zhangjiagang SBFR15 or equivalent

J2: Power Interrupt

CviLux CP35 2P*H00 (black); terminal part number 43030-0007

Mating connector is Molex Micro Fit Jr., Molex part number 43025-0200, terminal part number 43030-0007.

The power interrupt switch is connected to a single pole single throw normally open push button (SPST N.O) switch. This can be connected to your docking station or computer’s power button.

J3: Audio Input

3mm jack

J4: USB Upstream Type B

Type B for connecting to the computer

LX1200TI User’s Guide (020-0512-01A)

25

Image 25
Contents LX1200TI Important Recycle Instruction Table of Contents Environmental Specifications Cleaning the Monitor PrecautionsUsage Notice A VehicleAbout Planar’s LX1200TI Touch Monitor IntroductionFront View LX1200TI User’s Guide 020-0512-01A Bottom View Features Package Overview Before Installing InstallationKeep the following in mind while installing the monitor Installing the LX1200TI monitor consists of three stepsEdges of the monitor Mounting the MonitorIRtouch Install 14 LX1200TI User’s Guide 020-0512-01A LX1200TI User’s Guide 020-0512-01A 16 LX1200TI User’s Guide 020-0512-01A Connecting the Monitor 18 LX1200TI User’s Guide 020-0512-01A Front Panel Controls User ControlsTurning the Monitor On and Off Using the TouchscreenNavigating the Touchscreen Cleaning the Monitor Problem No sound Troubleshooting the MonitorAppendix Specifications DimensionsVideo Specifications Electrical SpecificationsSafety Immunity CharacteristicsElectromagnetic Compatibility EMC ESD, 6 kV contact and 8 kV air discharge EmissionsEnvironmental Specifications ConnectorsPIN Number Signal Addendum a Softkey Install GuidePlanar Softkey Use Function buttons are mapped out of the box as28 LX1200TI User’s Guide 020-0512-01A Planar Systems, Inc Support and Service