Oregon Scientific RAR601 user manual Setup Sensor, Data Transmission

Page 8

SETUP SENSOR

1.Open the remote sensor battery compartment with a small Phillips screwdriver.

2.Insert the batteries, matching the polarity as shown in the battery compartment.

3.Place the sensor near the main unit. Press RESET on the main unit to initiate signal sending between the sensor and the main unit. The reception icon on the main unit will blink for approximately 3 minutes while it is searching for the sensor. (Refer to the Sensor Data Transmission section for more information.)

4.Close the remote sensor battery compartment.

5.Secure the sensor in the desired location using the wall mount or table stand.

7

For best results:

Insert the batteries before you mount the sensor.

Place the sensor out of direct sunlight and moisture.

Do not place the sensor more than 30 meters (98 feet) from the main (indoor) unit.

Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls, and furniture.

Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects.

Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission.

You may need to experiment with various locations to get the best results.

DATA TRANSMISSION

Data is sent from the sensor(s) every 78 seconds. The reception icon shown in the Outdoor Temperature Area shows the status.

EN

RAR601 lab test R2

7

1/17/04, 4:47 PM

Image 8
Contents Wireless Thermo Clock Model RAR601 Contents Introduction About Oregon ScientificProduct Overview Front ViewBack View Remote Sensor Change Settings Getting StartedRemote Sensor BatteriesSetup Sensor Data TransmissionSwitch Clock Display ClockSearch for Sensor SET ClockAlarm TemperatureReset System Safety and CareTroubleshooting SpecificationsFCC Statement Declaration of Conformity Oregon Scientific. All rights reserved