InFocus LP 860 manual Replacing the projection lamp

Page 40

6To remove a lens, push the lever inside the lens housing and turn the lens counterclockwise until it stops. Remove the lens.

7To install a new lens, place it in the opening through the front of the pro- jector, aligning the red dot (near the base of the lens) with the red dot on the projector. Turn clockwise until you feel the lens click into place.

8Tighten the captive screw to the lens housing door. Place the front bezel back onto the projector and replace the two screws on the bottom of the projector. Replace the cover that protects the lens and the lamp housing on top of the projector.

lever inside

lens housing

Replacing the projection lamp

The lamp hour timer in the About menu counts the number of hours the lamp has been in use. Twenty hours before the specified end of the lamp’s life, the message “Change lamp” briefly appears on the projected screen. You can order new lamp modules from your dealer. See the Accessories cat- alog that came with the projector or visit our website for information.

1Turn off the projector and unplug the power cable.

2Wait 60 minutes to allow the projector to cool thoroughly.

3Gently place a flathead screwdriver into the slot on the top of the projec- tor (it is by the right speaker) and slide the small lever toward the right speaker. The cover that protects the lamp housing and the lens pops up.

About menu

turn off and unplug the projector

wait 60 minutes

cover

The lamp module is on the right.

4 Loosen the three captive screws on the lamp module.

slide lever in slot to pop open cover

40

Image 40
Contents USER’S Guide Trademarks Table of Contents Important Operating Considerations for Safety Accessories Projector components and features backIntroduction Online RegistrationConnector Panel Positioning the projector Required computer connections Connecting a computerOptional computer connections Visit our website for information on ProjectorNet Displaying a computer image First-time projector use with Windows Wizard launches two times For Windows 2000, Windows ME, and Windows XPAdjusting the image Standard video connections Connecting a video deviceOptional video connections Connect BNC cables Displaying a video image You can also adjust the zoom and focus via the menus. See Troubleshooting your setup Power SaveShutting down the projector Screen SaveSolution Computer image projectedRange Out Image clear and not cropped Page Color Lamp won’t turn on, Lamp LED blinking red Lamp won’t turn on, Temp LED solid redLamp may need to be replaced Lamp turns on Still having problems? Using the keypad buttons Using the remote control Troubleshooting the remoteTroubleshooting audio Using the audioConnecting external speakers Presentation features Optimizing computer imagesOptimizing video images Customizing the projectorUsing the menus Picture menu Presets Advanced settings Settings menu Screen Save PiP Enable PiP Position Effect Key Network Cleaning the lens MaintenanceChanging the lens Replacing the projection lamp Resetting the lamp timer Using the security lock Cleaning the dust filterTroubleshooting Projected image size AppendixWidth Image Feet/m LED Behavior LED color/behavior MeaningRS-232 commands Communication ConfigurationCommand Format Setting ValueError Conditions LimitationsINT at RW Disable Enable IR Receiver front IRF at RW = Japanese = Korean = Portuguese = Russian = Norwegian NND Page Ntsc Index NumericsPage XGA Limited Warranty Warranty Limitation and ExclusionDisclaimer of Unstated Warranties
Related manuals
Manual 50 pages 52.79 Kb