Warning

Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/ Data Processing Equipment ANSI/NFPA 75.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio / TV technician for help.

This Class B digital apparatus complies with Canadian ICES-003.

NOTE:

When you use an RGB cable (not supplied), use an RGB cable including the ferrite core (not supplied) on both ends of the cable. If you do not this, this monitor will not conform to mandatory FCC standards.

NOTE:

When you use the power cable (supplied), use the supplied ferrite cores. Set the ferrite cores (supplied) on both ends of the power cable (supplied), and then use the bands (supplied) to fasten the ferrite cores (supplied) to the power cable (supplied). If you do not this, this monitor will not conform to mandatory FCC standards.

Power cable (supplied)

bandband

corecore

NOTE:

When you use a remote cable (not supplied), use the supplied ferrite core. Wind the remote cable (not supplied) around the ferrite core (supplied) once, and then fasten the catch. If you do not this, this monitor will not conform to mandatory FCC standards.

Remote cable (not supplied)

To plasma monitor

core

5

Caution

This model is for use with the following optional accessories. Use with other optional accessories is capable of resulting in instability causing possible injury.

Manufacturer’s name: D&M Holdings Inc.

Stand: AS6150 for PD6001

Please contact Marantz America, Inc. for approved optional accessories.

WARNING

This product equipped with a three-wire grounding (earthed) plug - a plug that has a third (grounding) pin. This plug only fits a grounding-type power outlet. If you are unable to insert the plug into an outlet, contact a licensed electrician to replace the outlet with a properly grounded one. Do not defeat the safety purpose of the grounding plug.

Operating Environment: PD6001

Operating environment temperature and humidity:

0°C to +40 °C (+32 °F to +104 °F); less than 80 %RH (cooling vents not blocked)

Do not install this unit in a poorly ventilated area, or in locations exposed to high humidity or direct sunlight (or strong artificial light)

A NOTE ABOUT RECYCLING

This product’s packaging materials are

recyclable and can be reused. This product and the accessories packed together are the applicable product to the WEEE directive except batteries.

Please dispose of any materials in accordance with your local recycling regulations.

When discarding the unit, comply with your local rules or regulations.

Batteries should never be thrown away or incinerated but disposed of in accordance with your local regulations concerning chemical wastes.

EUROPE ONLY

CAUTION

When disposing of used batteries, please comply with governmental regulations or environmental public instruction’s rules that apply in your country/area.

Image 6
Contents Model PD6001 User Guide Important Safety Instructions Additional Safety InformationAvertissment Informations de Sécurité SupplémentairesPrecautions Important InformationRecommandations importantes PrécautionAvertissements et précautions de sécurité Operating Environment PD6001 Avertissement RemarqueContents Installation Ventilation Requirements for enclosure mountingCable Management Using the remote controlBattery Installation and Replacement Operating RangePart Names and Function Turns the monitor’s power on and offReceives the signals from the remote control Front ViewRear View/ Terminal Board PD6001Remote Control Basic Operations When viewing videos or digital video discs Wide Operations Supported resolution Wide Screen Operation with Computer SignalsWhen wide signals are input Normal size screen 43 or SxgaOperations in the Side-by-side mode Split Screen OperationsShowing a couple of pictures on the screen at the same time Adjusting the OSM controls Operations in the Picture-in-picture modeSelecting the input signals to be displayed Zooming in on a specific input Advanced menu mode Menu OperationsMenu Tree Main menu Sub menu Sub menu 3 Sub menu Restoring the factory default settings ResetAdjusting the picture Picture Settings MenuStoring picture settings Reducing noise in the pictureSetting the picture to suit the movie Setting the color temperatureAdjusting the color to the desired level  Adjusting the white balanceAdjusting the colors Making the Low Tone adjustmentsAdjusting the pedestal level black level Changing the Gamma CurveAudio Settings Menu Image Adjust Settings MenuSetting the allocation of the audio and DVD/ HD connectors SET UP Settings Menu Setting the black level for Hdmi signal Setting the video signal formatSetting the background color when no signal is being input Setting the position of the menu Etting the screen size for S1/S2 video inputTurning on/off the menu display Setting the menu mode Function Settings MenuResetting to the default values Setting the power management for computer imagesDisplaying the entire image during Digital Zoom operations ON/STANDBY indicatorSetting the Input Skip Displaying still images in the sub screen Orbiter settings  When set to Auto Peak Bright settings Reducing image retention Soft Focus settings Setting Closed Caption INVERSE/WHITE Settings  OSM Orbiter settingsSignal Information Menu Setting the power on modeReducing the brightness of Closed Caption External Control Pin AssignmentsConnection Example Connection Example Connecting an STBConnection with STB 1/8 Stereo Mini cable must be purchased separatelyTroubleshooting Symptom Checks RemedySpecifications PD6001 Supported resolution PD6001 Computer input signals supported by this systemCVT standard compliant KHz 169Is a registered trademark